First Solar Inc FS-6455A-P-B is a 455.0 W STC (421.2 W PTC) CdTe solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 18.06% efficiency, 222.0 V Voc at 25 C, and 243.06 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
421.2 W
Voc @ 25C
222.0 V
Efficiency
18.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6455A-P-B Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-6455A-P-B handles rooftop heat (421.2 W PTC), 8 kW sizing, and cold winter string voltage.

First Solar Inc builds the First Solar Inc FS-6455A-P-B (CdTe) as a modern high-density residential and light-commercial module delivering 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). Compared against Applied Materials Full Size Tandem Junction (458.0 W), this model holds strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Higher 222.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 4.02 A overcurrent floor served by a 15 A breaker.

Where Does First Solar Inc FS-6455A-P-B Fall Across Listed CEC Models?

Where First Solar Inc FS-6455A-P-B (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6455A-P-B (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 455.0 W

What Dataset Percentiles Define First Solar Inc FS-6455A-P-B?

Percentile placement of First Solar Inc FS-6455A-P-B across power density (180.6 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-6455A-P-B Engineering BenchmarksPercentile comparison of First Solar Inc FS-6455A-P-B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention92.6%Module Efficiency18.06%

What Do the Dataset Ranks Show for First Solar Inc FS-6455A-P-B?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6455A-P-B specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #14,990

18.06% Aperture Efficiency

Power density 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 243.06 V at -10 C (486.1 V string) and 249.07 V at -20 C (2 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,582 W PTC; NEC 690.8 OCPD floor is 4.02 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 222.0 * (1 + (-0.271/100) * (-10 - 25)) = 243.06 V | OCPD = 1.56 * 2.58 = 4.02 A

Inputs from CEC Modules.csv for First Solar Inc FS-6455A-P-B: Voc=222.0 V, beta_Voc=-0.271%/C, Isc=2.58 A, STC=455.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (486.1 V); 18 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6455A-P-B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6455A-P-B.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6455A-P-B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 421.2 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 222.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 187.8 V / 2.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.06% (2.52 m2) Array roof footprint density
Cell Count & Technology 268 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6455A-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6455A-P-B (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 380 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 488 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 597 sq ft $2,505 $4,236

How Many First Solar Inc FS-6455A-P-B Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-6455A-P-B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=222.0V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 249.07 V 2 panels 498.1 V 4 panels
-10 C (14 F) 243.06 V 2 panels 486.1 V 4 panels
0 C (32 F) 237.04 V 2 panels 474.1 V 4 panels
25 C (77 F STC) 222.0 V 2 panels 444.0 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6455A-P-B?

Alternative CEC solar modules from competing brands near First Solar Inc FS-6455A-P-B (455.0 W), including Applied Materials Full Size Tandem Junction.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Tandem Junction
Applied Materials
458.0 W +3.0 W 280.0 V 8.01% 91.7%
Heliene 96M460
Heliene
460.0 W +5.0 W 61.79 V 18.25% 90.4%
Heliene 96M475
Heliene
475.0 W +20.0 W 62.39 V 18.85% 90.5%
CSI Solar Co Ltd CS3Y-460P
CSI Solar Co Ltd
460.0 W +5.0 W 52.0 V 20.09% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6455A-P-B?

Evaluate First Solar Inc FS-6455A-P-B (455.0 W STC, 222.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6455A-P-B reaches 249.07 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6455A-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6455A-P-B 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 421.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6455A-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6455A-P-B?

Multiplying First Solar Inc FS-6455A-P-B's 2.58 A short-circuit current by 1.56 equals 4.02 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-6455A-P-B pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 243.06 V cold Voc at 14 F and handles 2.58 A Isc; string inverters cap First Solar Inc FS-6455A-P-B at 2 panels on 600 V.

Is First Solar Inc FS-6455A-P-B eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6455A-P-B rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.