First Solar Inc FS-6455-P is a 455.0 W STC (426.7 W PTC) CdTe solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 18.06% efficiency, 222.0 V Voc at 25 C, and 243.06 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 426.7 W
- Voc @ 25C
- 222.0 V
- Efficiency
- 18.06%
How Does First Solar Inc FS-6455-P Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6455-P handles rooftop heat (426.7 W PTC), 8 kW sizing, and cold winter string voltage.
First Solar Inc builds the First Solar Inc FS-6455-P (CdTe) as a modern high-density residential and light-commercial module delivering 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). Compared against Applied Materials Full Size Tandem Junction (458.0 W), this model holds strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677). Higher 222.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 4.02 A overcurrent floor served by a 15 A breaker.
Where Does First Solar Inc FS-6455-P Fall Across Listed CEC Models?
Where First Solar Inc FS-6455-P (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6455-P?
Percentile placement of First Solar Inc FS-6455-P across power density (180.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6455-P?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6455-P specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 445.0 W CdTe median.
18.06% Aperture Efficiency
Power density 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 243.06 V at -10 C (486.1 V string) and 249.07 V at -20 C (2 max).
18 Panels = 8,190 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,681 W PTC; NEC 690.8 OCPD floor is 4.02 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 222.0 * (1 + (-0.271/100) * (-10 - 25)) = 243.06 V | OCPD = 1.56 * 2.58 = 4.02 A
Inputs from CEC Modules.csv for First Solar Inc FS-6455-P: Voc=222.0 V, beta_Voc=-0.271%/C, Isc=2.58 A, STC=455.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (486.1 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6455-P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6455-P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 426.7 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 222.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 187.8 V / 2.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.06% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6455-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6455-P (455.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 380 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 488 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 597 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-6455-P Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6455-P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 249.07 V | 2 panels | 498.1 V | 4 panels |
| -10 C (14 F) | 243.06 V | 2 panels | 486.1 V | 4 panels |
| 0 C (32 F) | 237.04 V | 2 panels | 474.1 V | 4 panels |
| 25 C (77 F STC) | 222.0 V | 2 panels | 444.0 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6455-P?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6455-P (455.0 W), including Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | +3.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M460 Heliene |
460.0 W | +5.0 W | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +20.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | +5.0 W | 52.0 V | 20.09% | 93.1% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6455-P?
Evaluate First Solar Inc FS-6455-P (455.0 W STC, 222.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6455-P reaches 249.07 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6455-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6455-P 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6455-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6455-P?
Multiplying First Solar Inc FS-6455-P's 2.58 A short-circuit current by 1.56 equals 4.02 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6455-P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 243.06 V cold Voc at 14 F and handles 2.58 A Isc; string inverters cap First Solar Inc FS-6455-P at 2 panels on 600 V.
Is First Solar Inc FS-6455-P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6455-P rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)