First Solar Inc FS-6455-P-B-2 is a 455.0 W STC (432.3 W PTC) Thin Film solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 18.06% efficiency, 228.69 V Voc at 25 C, and 246.78 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 432.3 W
- Voc @ 25C
- 228.69 V
- Efficiency
- 18.06%
How Does First Solar Inc FS-6455-P-B-2 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6455-P-B-2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 106 Thin Film listings from First Solar Inc and peers, First Solar Inc FS-6455-P-B-2 stands 337.5 W above the 117.5 W Thin Film median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (14 panels) to 10 kW (22 panels) yields $1,594-$2,505/yr in baseline US bill offset. Higher 228.69 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6455-P-B-2 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6455-P-B-2 (455.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6455-P-B-2?
Dataset percentiles tracking First Solar Inc FS-6455-P-B-2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6455-P-B-2?
Benchmark highlights for First Solar Inc FS-6455-P-B-2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 117.5 W Thin Film median.
18.06% Aperture Efficiency
Power density 180.6 W/m2 (1.85 percentage points below 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 246.78 V at -10 C (493.6 V string) and 251.95 V at -20 C (2 max).
18 Panels = 8,190 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,781 W PTC; NEC 690.8 OCPD floor is 4.21 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 228.69 * (1 + (-0.226/100) * (-10 - 25)) = 246.78 V | OCPD = 1.56 * 2.7 = 4.21 A
Inputs from CEC Modules.csv for First Solar Inc FS-6455-P-B-2: Voc=228.69 V, beta_Voc=-0.226%/C, Isc=2.7 A, STC=455.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (493.6 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6455-P-B-2?
Official CEC datasheet figures for First Solar Inc FS-6455-P-B-2 (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 432.3 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 228.69 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 181.53 V / 2.51 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.06% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-6455-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6455-P-B-2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 380 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 488 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 597 sq ft | $2,505 | $4,236 |
How Many First Solar Inc FS-6455-P-B-2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6455-P-B-2 (246.78 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 251.95 V | 2 panels | 503.9 V | 3 panels |
| -10 C (14 F) | 246.78 V | 2 panels | 493.6 V | 4 panels |
| 0 C (32 F) | 241.61 V | 2 panels | 483.2 V | 4 panels |
| 25 C (77 F STC) | 228.69 V | 2 panels | 457.4 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6455-P-B-2?
Competing CEC solar panels closest to First Solar Inc FS-6455-P-B-2 in nameplate wattage and Voc, starting with Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | +3.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M460 Heliene |
460.0 W | +5.0 W | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +20.0 W | 62.39 V | 18.85% | 90.5% |
| CSI Solar Co Ltd CS3Y-460P CSI Solar Co Ltd |
460.0 W | +5.0 W | 52.0 V | 20.09% | 93.1% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6455-P-B-2?
Evaluate First Solar Inc FS-6455-P-B-2 (455.0 W STC, 228.69 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6455-P-B-2 reaches 251.95 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6455-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6455-P-B-2 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 432.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6455-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6455-P-B-2?
Multiplying First Solar Inc FS-6455-P-B-2's 2.7 A short-circuit current by 1.56 equals 4.21 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6455-P-B-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 246.78 V cold Voc at 14 F and handles 2.7 A Isc; string inverters cap First Solar Inc FS-6455-P-B-2 at 2 panels on 600 V.
Is First Solar Inc FS-6455-P-B-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6455-P-B-2 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)