First Solar Inc FS-6450A-P-x is a 450.0 W STC (414.4 W PTC) CdTe solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 17.86% efficiency, 221.1 V Voc at 25 C, and 242.92 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
414.4 W
Voc @ 25C
221.1 V
Efficiency
17.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6450A-P-x Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6450A-P-x (CdTe) residential solar systems.

Homeowners evaluating First Solar Inc FS-6450A-P-x need 14 panels for 6 kW or 18 panels (488 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.282%/C) pushes open-circuit voltage to 242.92 V at 14 F and 249.16 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-6450A-P-x Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6450A-P-x (450.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6450A-P-x (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 450.0 W

What Dataset Percentiles Define First Solar Inc FS-6450A-P-x?

Relative ranking of First Solar Inc FS-6450A-P-x across nameplate watts, 92.1% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-6450A-P-x Engineering BenchmarksPercentile comparison of First Solar Inc FS-6450A-P-x wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention92.1%Module Efficiency17.86%

What Do the Dataset Ranks Show for First Solar Inc FS-6450A-P-x?

Summary of First Solar Inc FS-6450A-P-x output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #15,283

17.86% Aperture Efficiency

Power density 178.6 W/m2 (2.05 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 242.92 V at -10 C (485.8 V string) and 249.16 V at -20 C (2 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 45.4 m2 (488 sq ft) producing 7,459 W PTC; NEC 690.8 OCPD floor is 4.01 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 221.1 * (1 + (-0.282/100) * (-10 - 25)) = 242.92 V | OCPD = 1.56 * 2.57 = 4.01 A

Inputs from CEC Modules.csv for First Solar Inc FS-6450A-P-x: Voc=221.1 V, beta_Voc=-0.282%/C, Isc=2.57 A, STC=450.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (485.8 V); 18 panels for 8 kW (488 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6450A-P-x?

Complete CEC test sheet for First Solar Inc FS-6450A-P-x including Isc (2.57 A), Voc (221.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6450A-P-x.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 414.4 W (92.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 221.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.57 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 186.8 V / 2.41 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.282 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.86% (2.52 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6450A-P-x Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6450A-P-x.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 380 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 488 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 624 sq ft $2,591 $4,380

How Many First Solar Inc FS-6450A-P-x Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6450A-P-x (221.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=221.1V and beta_Voc=-0.282%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 249.16 V 2 panels 498.3 V 4 panels
-10 C (14 F) 242.92 V 2 panels 485.8 V 4 panels
0 C (32 F) 236.69 V 2 panels 473.4 V 4 panels
25 C (77 F STC) 221.1 V 2 panels 442.2 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6450A-P-x?

Four comparable CEC modules such as Applied Materials Full Size Tandem Junction (458.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Tandem Junction
Applied Materials
458.0 W +8.0 W 280.0 V 8.01% 91.7%
Heliene 96M460
Heliene
460.0 W +10.0 W 61.79 V 18.25% 90.4%
Heliene 96M475
Heliene
475.0 W +25.0 W 62.39 V 18.85% 90.5%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6450A-P-x?

Evaluate First Solar Inc FS-6450A-P-x (450.0 W STC, 221.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6450A-P-x reaches 249.16 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6450A-P-x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6450A-P-x 8 kW Residential Fit

Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 414.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6450A-P-x by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-6450A-P-x PTC wattage (414.4 W) lower than STC (450.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 414.4 W PTC (92.1% retention) across First Solar Inc FS-6450A-P-x's 2.52 m2 aperture.

Who should skip First Solar Inc FS-6450A-P-x on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 First Solar Inc FS-6450A-P-x panels (488 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.

What is the 1,000 V commercial string limit for First Solar Inc FS-6450A-P-x?

On 1,000 V commercial inverters at -10 C (242.92 V cold Voc), First Solar Inc FS-6450A-P-x fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6450A-P-x.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.