First Solar Inc FS-6450A-P-B is a 450.0 W STC (416.5 W PTC) CdTe solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 17.86% efficiency, 221.1 V Voc at 25 C, and 242.07 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 416.5 W
- Voc @ 25C
- 221.1 V
- Efficiency
- 17.86%
How Does First Solar Inc FS-6450A-P-B Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-6450A-P-B (450.0 W STC) vs. Applied Materials Full Size Tandem Junction across 131 CEC CdTe solar modules.
Built with 268 CdTe cells, First Solar Inc FS-6450A-P-B pairs strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677) with 221.1 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,497 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Applied Materials Full Size Tandem Junction offers a 458.0 W alternative.
Where Does First Solar Inc FS-6450A-P-B Fall Across Listed CEC Models?
Plots First Solar Inc FS-6450A-P-B at 450.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6450A-P-B?
Benchmarks First Solar Inc FS-6450A-P-B on STC wattage, thermal PTC/STC retention, and 17.86 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-6450A-P-B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6450A-P-B by First Solar Inc.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 445.0 W CdTe median.
17.86% Aperture Efficiency
Power density 178.6 W/m2 (2.05 percentage points below 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 242.07 V at -10 C (484.1 V string) and 248.06 V at -20 C (2 max).
18 Panels = 8,100 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,497 W PTC; NEC 690.8 OCPD floor is 4.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 221.1 * (1 + (-0.271/100) * (-10 - 25)) = 242.07 V | OCPD = 1.56 * 2.57 = 4.01 A
Inputs from CEC Modules.csv for First Solar Inc FS-6450A-P-B: Voc=221.1 V, beta_Voc=-0.271%/C, Isc=2.57 A, STC=450.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (484.1 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6450A-P-B?
Laboratory test ratings recorded for First Solar Inc FS-6450A-P-B (CdTe) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 416.5 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 221.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 186.8 V / 2.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.86% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6450A-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (488 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6450A-P-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 380 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 488 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 624 sq ft | $2,591 | $4,380 |
How Many First Solar Inc FS-6450A-P-B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-6450A-P-B (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 248.06 V | 2 panels | 496.1 V | 4 panels |
| -10 C (14 F) | 242.07 V | 2 panels | 484.1 V | 4 panels |
| 0 C (32 F) | 236.08 V | 2 panels | 472.2 V | 4 panels |
| 25 C (77 F STC) | 221.1 V | 2 panels | 442.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6450A-P-B?
Closest cross-brand CEC competitors to First Solar Inc FS-6450A-P-B matched near 450.0 W STC and 221.1 V Voc, led by Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | +8.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M460 Heliene |
460.0 W | +10.0 W | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +25.0 W | 62.39 V | 18.85% | 90.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6450A-P-B?
Evaluate First Solar Inc FS-6450A-P-B (450.0 W STC, 221.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6450A-P-B reaches 248.06 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6450A-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6450A-P-B 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6450A-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6450A-P-B?
Multiplying First Solar Inc FS-6450A-P-B's 2.57 A short-circuit current by 1.56 equals 4.01 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6450A-P-B pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 242.07 V cold Voc at 14 F and handles 2.57 A Isc; string inverters cap First Solar Inc FS-6450A-P-B at 2 panels on 600 V.
Is First Solar Inc FS-6450A-P-B eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6450A-P-B rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)