First Solar Inc FS-6450A-P-B-2 is a 450.0 W STC (427.3 W PTC) Thin Film solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 17.86% efficiency, 228.06 V Voc at 25 C, and 246.1 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 427.3 W
- Voc @ 25C
- 228.06 V
- Efficiency
- 17.86%
How Does First Solar Inc FS-6450A-P-B-2 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6450A-P-B-2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 450.0 W STC and 427.3 W PTC, First Solar Inc FS-6450A-P-B-2 sits +65.0 W vs all-CEC median (top 27.8%; higher than 72.2% of peers) among 21,677 listed modules. Power density reaches 178.6 W/m2 (2.05 percentage points below 19.91% CEC median). Higher 228.06 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Tandem Junction rates 458.0 W.
Where Does First Solar Inc FS-6450A-P-B-2 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6450A-P-B-2 (450.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6450A-P-B-2?
Dataset percentiles tracking First Solar Inc FS-6450A-P-B-2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6450A-P-B-2?
Benchmark highlights for First Solar Inc FS-6450A-P-B-2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 117.5 W Thin Film median.
17.86% Aperture Efficiency
Power density 178.6 W/m2 (2.05 percentage points below 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 246.1 V at -10 C (492.2 V string) and 251.25 V at -20 C (2 max).
18 Panels = 8,100 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,691 W PTC; NEC 690.8 OCPD floor is 4.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 228.06 * (1 + (-0.226/100) * (-10 - 25)) = 246.1 V | OCPD = 1.56 * 2.69 = 4.2 A
Inputs from CEC Modules.csv for First Solar Inc FS-6450A-P-B-2: Voc=228.06 V, beta_Voc=-0.226%/C, Isc=2.69 A, STC=450.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (492.2 V); 18 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6450A-P-B-2?
Official CEC datasheet figures for First Solar Inc FS-6450A-P-B-2 (Thin Film) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 427.3 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 228.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.69 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 180.53 V / 2.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.86% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-6450A-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6450A-P-B-2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 380 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 488 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 624 sq ft | $2,591 | $4,380 |
How Many First Solar Inc FS-6450A-P-B-2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6450A-P-B-2 (246.1 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 251.25 V | 2 panels | 502.5 V | 3 panels |
| -10 C (14 F) | 246.1 V | 2 panels | 492.2 V | 4 panels |
| 0 C (32 F) | 240.95 V | 2 panels | 481.9 V | 4 panels |
| 25 C (77 F STC) | 228.06 V | 2 panels | 456.1 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6450A-P-B-2?
Competing CEC solar panels closest to First Solar Inc FS-6450A-P-B-2 in nameplate wattage and Voc, starting with Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | +8.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M460 Heliene |
460.0 W | +10.0 W | 61.79 V | 18.25% | 90.4% |
| Heliene 96M475 Heliene |
475.0 W | +25.0 W | 62.39 V | 18.85% | 90.5% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
450.0 W | Tie (0 W) | 50.0 V | 21.23% | 92.5% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6450A-P-B-2?
Evaluate First Solar Inc FS-6450A-P-B-2 (450.0 W STC, 228.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6450A-P-B-2 reaches 251.25 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 488 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (488 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6450A-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6450A-P-B-2 8 kW Residential Fit
Needs 18 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6450A-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6450A-P-B-2 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6450A-P-B-2 cold Voc rises from 228.06 V to 246.1 V (beta_Voc -0.226%/C), capping a 600 V string at 2 panels (492.2 V).
How much roof area does an 8 kW array of First Solar Inc FS-6450A-P-B-2 need?
An 8 kW DC system uses 18 First Solar Inc FS-6450A-P-B-2 modules (8,100 W STC / 7,691 W PTC), covering roughly 488 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does First Solar Inc FS-6450A-P-B-2 compare against Applied Materials Full Size Tandem Junction?
First Solar Inc FS-6450A-P-B-2 outputs 450.0 W STC (228.06 V Voc, rank #5,679 of 21,677), while Applied Materials Full Size Tandem Junction delivers 458.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)