Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6435-P-B-2 is a 435.0 W STC (413.0 W PTC) Thin Film solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 17.26% efficiency, 226.14 V Voc at 25 C, and 244.03 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
413.0 W
Voc @ 25C
226.14 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6435-P-B-2 Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-6435-P-B-2 handles rooftop heat (413.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-6435-P-B-2 exhibits 2.67 A short-circuit current, requiring a 4.17 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #6,850 of 21,677 (317.5 W above the 117.5 W Thin Film median), this modern high-density residential and light-commercial module covers 47.9 m2 for an 8 kW system (23 panels for 10 kW). Higher 226.14 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

Where Does First Solar Inc FS-6435-P-B-2 Fall Across Listed CEC Models?

Where First Solar Inc FS-6435-P-B-2 (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6435-P-B-2 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 435.0 W

What Dataset Percentiles Define First Solar Inc FS-6435-P-B-2?

Percentile placement of First Solar Inc FS-6435-P-B-2 across power density (172.6 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-6435-P-B-2 Engineering BenchmarksPercentile comparison of First Solar Inc FS-6435-P-B-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.9%Module Efficiency17.26%

What Do the Dataset Ranks Show for First Solar Inc FS-6435-P-B-2?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6435-P-B-2 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.6 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 244.03 V at -10 C (488.1 V string) and 249.14 V at -20 C (2 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 47.9 m2 (515 sq ft) producing 7,847 W PTC; NEC 690.8 OCPD floor is 4.17 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 226.14 * (1 + (-0.226/100) * (-10 - 25)) = 244.03 V | OCPD = 1.56 * 2.67 = 4.17 A

Inputs from CEC Modules.csv for First Solar Inc FS-6435-P-B-2: Voc=226.14 V, beta_Voc=-0.226%/C, Isc=2.67 A, STC=435.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (488.1 V); 19 panels for 8 kW (515 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6435-P-B-2?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6435-P-B-2.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6435-P-B-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 413.0 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 226.14 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.67 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 177.49 V / 2.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.226 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (2.52 m2) Array roof footprint density
Cell Count & Technology 268 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-6435-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6435-P-B-2 (435.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 380 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 515 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 624 sq ft $2,505 $4,236

How Many First Solar Inc FS-6435-P-B-2 Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-6435-P-B-2 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=226.14V and beta_Voc=-0.226%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 249.14 V 2 panels 498.3 V 4 panels
-10 C (14 F) 244.03 V 2 panels 488.1 V 4 panels
0 C (32 F) 238.92 V 2 panels 477.8 V 4 panels
25 C (77 F STC) 226.14 V 2 panels 452.3 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6435-P-B-2?

Alternative CEC solar modules from competing brands near First Solar Inc FS-6435-P-B-2 (435.0 W), including Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Single Junction Version 10
Applied Materials
414.0 W -21.0 W 194.2 V 7.24% 92.9%
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6435-P-B-2?

Evaluate First Solar Inc FS-6435-P-B-2 (435.0 W STC, 226.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6435-P-B-2 reaches 249.14 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6435-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6435-P-B-2 8 kW Residential Fit

Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 413.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6435-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-6435-P-B-2 PTC wattage (413.0 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 413.0 W PTC (94.9% retention) across First Solar Inc FS-6435-P-B-2's 2.52 m2 aperture.

Who should skip First Solar Inc FS-6435-P-B-2 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 First Solar Inc FS-6435-P-B-2 panels (515 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.

What is the 1,000 V commercial string limit for First Solar Inc FS-6435-P-B-2?

On 1,000 V commercial inverters at -10 C (244.03 V cold Voc), First Solar Inc FS-6435-P-B-2 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6435-P-B-2.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.