First Solar Inc FS-6430 is a 430.0 W STC (401.3 W PTC) CdTe solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 17.37% efficiency, 219.2 V Voc at 25 C, and 240.68 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 401.3 W
- Voc @ 25C
- 219.2 V
- Efficiency
- 17.37%
How Does First Solar Inc FS-6430 Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6430 handles rooftop heat (401.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, First Solar Inc FS-6430 exhibits 2.54 A short-circuit current, requiring a 3.96 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #7,266 of 21,677 (15.0 W below the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 47.0 m2 for an 8 kW system (24 panels for 10 kW). Higher 219.2 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6430 Fall Across Listed CEC Models?
Where First Solar Inc FS-6430 (430.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6430?
Percentile placement of First Solar Inc FS-6430 across power density (173.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6430?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6430 specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 445.0 W CdTe median.
17.37% Aperture Efficiency
Power density 173.7 W/m2 (2.54 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 240.68 V at -10 C (481.4 V string) and 246.82 V at -20 C (2 max).
19 Panels = 8,170 W STC
Occupies 47.0 m2 (506 sq ft) producing 7,625 W PTC; NEC 690.8 OCPD floor is 3.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 219.2 * (1 + (-0.28/100) * (-10 - 25)) = 240.68 V | OCPD = 1.56 * 2.54 = 3.96 A
Inputs from CEC Modules.csv for First Solar Inc FS-6430: Voc=219.2 V, beta_Voc=-0.28%/C, Isc=2.54 A, STC=430.0 W, Area=2.475 m2.
Result: 2 panels max on 600 V (481.4 V); 19 panels for 8 kW (506 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6430?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6430.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 401.3 W (93.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 219.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 182.6 V / 2.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.28 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.37% (2.475 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6430 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6430 (430.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 373 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 506 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 639 sq ft | $2,583 | $4,368 |
How Many First Solar Inc FS-6430 Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6430 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 246.82 V | 2 panels | 493.6 V | 4 panels |
| -10 C (14 F) | 240.68 V | 2 panels | 481.4 V | 4 panels |
| 0 C (32 F) | 234.54 V | 2 panels | 469.1 V | 4 panels |
| 25 C (77 F STC) | 219.2 V | 2 panels | 438.4 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6430?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6430 (430.0 W), including Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -16.0 W | 194.2 V | 7.24% | 92.9% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6430?
Evaluate First Solar Inc FS-6430 (430.0 W STC, 219.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6430 reaches 246.82 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 506 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (506 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6430 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6430 8 kW Residential Fit
Needs 19 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 401.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6430 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6430 PTC wattage (401.3 W) lower than STC (430.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 401.3 W PTC (93.3% retention) across First Solar Inc FS-6430's 2.475 m2 aperture.
Who should skip First Solar Inc FS-6430 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 First Solar Inc FS-6430 panels (506 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.
What is the 1,000 V commercial string limit for First Solar Inc FS-6430?
On 1,000 V commercial inverters at -10 C (240.68 V cold Voc), First Solar Inc FS-6430 fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6430.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)