First Solar Inc FS-6430-P is a 430.0 W STC (402.8 W PTC) CdTe solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 17.06% efficiency, 219.2 V Voc at 25 C, and 239.99 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 402.8 W
- Voc @ 25C
- 219.2 V
- Efficiency
- 17.06%
How Does First Solar Inc FS-6430-P Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6430-P (CdTe) residential solar systems.
Homeowners evaluating First Solar Inc FS-6430-P need 14 panels for 6 kW or 19 panels (515 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.271%/C) pushes open-circuit voltage to 239.99 V at 14 F and 245.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-6430-P Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6430-P (430.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6430-P?
Relative ranking of First Solar Inc FS-6430-P across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6430-P?
Summary of First Solar Inc FS-6430-P output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 445.0 W CdTe median.
17.06% Aperture Efficiency
Power density 170.6 W/m2 (2.85 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 239.99 V at -10 C (480.0 V string) and 245.93 V at -20 C (2 max).
19 Panels = 8,170 W STC
Occupies 47.9 m2 (515 sq ft) producing 7,653 W PTC; NEC 690.8 OCPD floor is 3.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 219.2 * (1 + (-0.271/100) * (-10 - 25)) = 239.99 V | OCPD = 1.56 * 2.54 = 3.96 A
Inputs from CEC Modules.csv for First Solar Inc FS-6430-P: Voc=219.2 V, beta_Voc=-0.271%/C, Isc=2.54 A, STC=430.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (480.0 V); 19 panels for 8 kW (515 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6430-P?
Complete CEC test sheet for First Solar Inc FS-6430-P including Isc (2.54 A), Voc (219.2 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 402.8 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 219.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 182.6 V / 2.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.06% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6430-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6430-P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 380 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 515 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 651 sq ft | $2,583 | $4,368 |
How Many First Solar Inc FS-6430-P Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6430-P (219.2 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 245.93 V | 2 panels | 491.9 V | 4 panels |
| -10 C (14 F) | 239.99 V | 2 panels | 480.0 V | 4 panels |
| 0 C (32 F) | 234.05 V | 2 panels | 468.1 V | 4 panels |
| 25 C (77 F STC) | 219.2 V | 2 panels | 438.4 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6430-P?
Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -16.0 W | 194.2 V | 7.24% | 92.9% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6430-P?
Evaluate First Solar Inc FS-6430-P (430.0 W STC, 219.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6430-P reaches 245.93 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6430-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6430-P 8 kW Residential Fit
Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 402.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6430-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6430-P PTC wattage (402.8 W) lower than STC (430.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 402.8 W PTC (93.7% retention) across First Solar Inc FS-6430-P's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6430-P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 First Solar Inc FS-6430-P panels (515 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.
What is the 1,000 V commercial string limit for First Solar Inc FS-6430-P?
On 1,000 V commercial inverters at -10 C (239.99 V cold Voc), First Solar Inc FS-6430-P fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6430-P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)