First Solar Inc FS-6425A-P-B is a 425.0 W STC (392.8 W PTC) CdTe solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 16.87% efficiency, 218.9 V Voc at 25 C, and 239.66 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 425.0 W
- PTC Wattage
- 392.8 W
- Voc @ 25C
- 218.9 V
- Efficiency
- 16.87%
How Does First Solar Inc FS-6425A-P-B Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6425A-P-B (CdTe) residential solar systems.
First Solar Inc FS-6425A-P-B delivers 168.7 W/m2 (3.04 percentage points below 19.91% CEC median) and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 245.59 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Single Junction Version 10 (414.0 W).
Where Does First Solar Inc FS-6425A-P-B Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6425A-P-B (425.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6425A-P-B?
Relative ranking of First Solar Inc FS-6425A-P-B across nameplate watts, 92.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6425A-P-B?
Summary of First Solar Inc FS-6425A-P-B output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 36.5% STC Output
425.0 W STC (+40.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.87% Aperture Efficiency
Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 239.66 V at -10 C (479.3 V string) and 245.59 V at -20 C (2 max).
19 Panels = 8,075 W STC
Occupies 47.9 m2 (515 sq ft) producing 7,463 W PTC; NEC 690.8 OCPD floor is 3.96 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 218.9 * (1 + (-0.271/100) * (-10 - 25)) = 239.66 V | OCPD = 1.56 * 2.54 = 3.96 A
Inputs from CEC Modules.csv for First Solar Inc FS-6425A-P-B: Voc=218.9 V, beta_Voc=-0.271%/C, Isc=2.54 A, STC=425.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (479.3 V); 19 panels for 8 kW (515 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6425A-P-B?
Complete CEC test sheet for First Solar Inc FS-6425A-P-B including Isc (2.54 A), Voc (218.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 392.8 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 218.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 181.5 V / 2.34 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.87% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6425A-P-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6425A-P-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.38 kW | 407 sq ft | $1,597 | $2,700 |
| 8 kW Class | 19 | 8.07 kW | 515 sq ft | $2,020 | $3,415 |
| 10 kW Class | 24 | 10.2 kW | 651 sq ft | $2,553 | $4,317 |
How Many First Solar Inc FS-6425A-P-B Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6425A-P-B (218.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 245.59 V | 2 panels | 491.2 V | 4 panels |
| -10 C (14 F) | 239.66 V | 2 panels | 479.3 V | 4 panels |
| 0 C (32 F) | 233.73 V | 2 panels | 467.5 V | 4 panels |
| 25 C (77 F STC) | 218.9 V | 2 panels | 437.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6425A-P-B?
Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -11.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -15.0 W | 52.7 V | 21.03% | 94.1% |
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | -5.0 W | 48.8 V | 19.44% | 93.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | +10.0 W | 49.7 V | 20.71% | 91.8% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6425A-P-B?
Evaluate First Solar Inc FS-6425A-P-B (425.0 W STC, 218.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6425A-P-B reaches 245.59 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6425A-P-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6425A-P-B 8 kW Residential Fit
Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 392.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6425A-P-B by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6425A-P-B panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6425A-P-B cold Voc rises from 218.9 V to 239.66 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (479.3 V).
How much roof area does an 8 kW array of First Solar Inc FS-6425A-P-B need?
An 8 kW DC system uses 19 First Solar Inc FS-6425A-P-B modules (8,075 W STC / 7,463 W PTC), covering roughly 515 sq ft and saving ~$2,020/yr at 18.54 c/kWh.
How does First Solar Inc FS-6425A-P-B compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6425A-P-B outputs 425.0 W STC (218.9 V Voc, rank #7,622 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)