Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-6425-P — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6425-P is a 425.0 W STC (398.0 W PTC) CdTe solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 16.87% efficiency, 218.9 V Voc at 25 C, and 239.66 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
425.0 W
PTC Wattage
398.0 W
Voc @ 25C
218.9 V
Efficiency
16.87%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6425-P Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6425-P (CdTe) residential solar systems.

First Solar Inc FS-6425-P delivers 168.7 W/m2 (3.04 percentage points below 19.91% CEC median) and strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 245.59 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Single Junction Version 10 (414.0 W).

Where Does First Solar Inc FS-6425-P Fall Across Listed CEC Models?

Comparison of First Solar Inc FS-6425-P (425.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6425-P (425.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 425.0 W

What Dataset Percentiles Define First Solar Inc FS-6425-P?

Relative ranking of First Solar Inc FS-6425-P across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency.

First Solar Inc FS-6425-P Engineering BenchmarksPercentile comparison of First Solar Inc FS-6425-P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage425.0 WPTC/STC Retention93.6%Module Efficiency16.87%

What Do the Dataset Ranks Show for First Solar Inc FS-6425-P?

Summary of First Solar Inc FS-6425-P output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #7,622 / 21,677

Top 36.5% STC Output

425.0 W STC (+40.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #16,673

16.87% Aperture Efficiency

Power density 168.7 W/m2 (3.04 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 239.66 V at -10 C (479.3 V string) and 245.59 V at -20 C (2 max).

8 kW Reference Array

19 Panels = 8,075 W STC

Occupies 47.9 m2 (515 sq ft) producing 7,562 W PTC; NEC 690.8 OCPD floor is 3.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 218.9 * (1 + (-0.271/100) * (-10 - 25)) = 239.66 V | OCPD = 1.56 * 2.54 = 3.96 A

Inputs from CEC Modules.csv for First Solar Inc FS-6425-P: Voc=218.9 V, beta_Voc=-0.271%/C, Isc=2.54 A, STC=425.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (479.3 V); 19 panels for 8 kW (515 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6425-P?

Complete CEC test sheet for First Solar Inc FS-6425-P including Isc (2.54 A), Voc (218.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6425-P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 425.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 398.0 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 218.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.54 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 181.5 V / 2.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.87% (2.52 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6425-P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6425-P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.38 kW 407 sq ft $1,597 $2,700
8 kW Class 19 8.07 kW 515 sq ft $2,020 $3,415
10 kW Class 24 10.2 kW 651 sq ft $2,553 $4,317

How Many First Solar Inc FS-6425-P Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for First Solar Inc FS-6425-P (218.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=218.9V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 245.59 V 2 panels 491.2 V 4 panels
-10 C (14 F) 239.66 V 2 panels 479.3 V 4 panels
0 C (32 F) 233.73 V 2 panels 467.5 V 4 panels
25 C (77 F STC) 218.9 V 2 panels 437.8 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6425-P?

Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Single Junction Version 10
Applied Materials
414.0 W -11.0 W 194.2 V 7.24% 92.9%
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -15.0 W 52.7 V 21.03% 94.1%
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W -5.0 W 48.8 V 19.44% 93.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W +10.0 W 49.7 V 20.71% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6425-P?

Evaluate First Solar Inc FS-6425-P (425.0 W STC, 218.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6425-P reaches 245.59 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6425-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6425-P 8 kW Residential Fit

Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 398.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6425-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-6425-P panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6425-P cold Voc rises from 218.9 V to 239.66 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (479.3 V).

How much roof area does an 8 kW array of First Solar Inc FS-6425-P need?

An 8 kW DC system uses 19 First Solar Inc FS-6425-P modules (8,075 W STC / 7,562 W PTC), covering roughly 515 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

How does First Solar Inc FS-6425-P compare against Applied Materials Full Size Single Junction Version 10?

First Solar Inc FS-6425-P outputs 425.0 W STC (218.9 V Voc, rank #7,622 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.