First Solar Inc FS-6420A-P-B-2 is a 420.0 W STC (398.3 W PTC) Thin Film solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 16.67% efficiency, 224.16 V Voc at 25 C, and 241.89 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 398.3 W
- Voc @ 25C
- 224.16 V
- Efficiency
- 16.67%
How Does First Solar Inc FS-6420A-P-B-2 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-6420A-P-B-2 (420.0 W STC) vs. Applied Materials Full Size Single Junction Version 10 across 106 CEC Thin Film solar modules.
Ranking #7,910 across 21,677 CEC solar panels (top 37.8%; higher than 62.2% of peers), First Solar Inc FS-6420A-P-B-2 operates as a modern high-density residential and light-commercial module sitting 302.5 W above the 117.5 W Thin Film median. Higher 224.16 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C). With strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677), 20 panels occupy 543 sq ft and offset roughly $2,102/yr at average US rates (or $3,555/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-6420A-P-B-2 Fall Across Listed CEC Models?
Plots First Solar Inc FS-6420A-P-B-2 at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6420A-P-B-2?
Benchmarks First Solar Inc FS-6420A-P-B-2 on STC wattage, thermal PTC/STC retention, and 16.67 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-6420A-P-B-2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6420A-P-B-2 by First Solar Inc.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 117.5 W Thin Film median.
16.67% Aperture Efficiency
Power density 166.7 W/m2 (3.24 percentage points below 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 241.89 V at -10 C (483.8 V string) and 246.96 V at -20 C (2 max).
20 Panels = 8,400 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,966 W PTC; NEC 690.8 OCPD floor is 4.13 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 224.16 * (1 + (-0.226/100) * (-10 - 25)) = 241.89 V | OCPD = 1.56 * 2.65 = 4.13 A
Inputs from CEC Modules.csv for First Solar Inc FS-6420A-P-B-2: Voc=224.16 V, beta_Voc=-0.226%/C, Isc=2.65 A, STC=420.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (483.8 V); 20 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6420A-P-B-2?
Laboratory test ratings recorded for First Solar Inc FS-6420A-P-B-2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 398.3 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 224.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 174.4 V / 2.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.67% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-6420A-P-B-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6420A-P-B-2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 407 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 543 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 651 sq ft | $2,523 | $4,266 |
How Many First Solar Inc FS-6420A-P-B-2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-6420A-P-B-2 (beta_Voc -0.226%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 246.96 V | 2 panels | 493.9 V | 4 panels |
| -10 C (14 F) | 241.89 V | 2 panels | 483.8 V | 4 panels |
| 0 C (32 F) | 236.83 V | 2 panels | 473.7 V | 4 panels |
| 25 C (77 F STC) | 224.16 V | 2 panels | 448.3 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6420A-P-B-2?
Closest cross-brand CEC competitors to First Solar Inc FS-6420A-P-B-2 matched near 420.0 W STC and 224.16 V Voc, led by Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -6.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -10.0 W | 52.7 V | 21.03% | 94.1% |
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6420A-P-B-2?
Evaluate First Solar Inc FS-6420A-P-B-2 (420.0 W STC, 224.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6420A-P-B-2 reaches 246.96 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6420A-P-B-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6420A-P-B-2 8 kW Residential Fit
Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 398.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6420A-P-B-2 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6420A-P-B-2 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6420A-P-B-2 cold Voc rises from 224.16 V to 241.89 V (beta_Voc -0.226%/C), capping a 600 V string at 2 panels (483.8 V).
How much roof area does an 8 kW array of First Solar Inc FS-6420A-P-B-2 need?
An 8 kW DC system uses 20 First Solar Inc FS-6420A-P-B-2 modules (8,400 W STC / 7,966 W PTC), covering roughly 543 sq ft and saving ~$2,102/yr at 18.54 c/kWh.
How does First Solar Inc FS-6420A-P-B-2 compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6420A-P-B-2 outputs 420.0 W STC (224.16 V Voc, rank #7,910 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)