Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-6405 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6405 is a 405.0 W STC (377.5 W PTC) CdTe solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 16.33% efficiency, 216.8 V Voc at 25 C, and 238.05 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
377.5 W
Voc @ 25C
216.8 V
Efficiency
16.33%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6405 Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6405: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 131 CdTe listings from First Solar Inc and peers, First Solar Inc FS-6405 stands 40.0 W below the 445.0 W CdTe median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,522-$2,533/yr in baseline US bill offset. Higher 216.8 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).

Where Does First Solar Inc FS-6405 Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6405 (405.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6405 (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 405.0 W

What Dataset Percentiles Define First Solar Inc FS-6405?

Dataset percentiles tracking First Solar Inc FS-6405 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-6405 Engineering BenchmarksPercentile comparison of First Solar Inc FS-6405 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.2%Module Efficiency16.33%

What Do the Dataset Ranks Show for First Solar Inc FS-6405?

Benchmark highlights for First Solar Inc FS-6405 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #17,619

16.33% Aperture Efficiency

Power density 163.3 W/m2 (3.58 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 238.05 V at -10 C (476.1 V string) and 244.12 V at -20 C (2 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 49.6 m2 (534 sq ft) producing 7,550 W PTC; NEC 690.8 OCPD floor is 3.93 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 216.8 * (1 + (-0.28/100) * (-10 - 25)) = 238.05 V | OCPD = 1.56 * 2.52 = 3.93 A

Inputs from CEC Modules.csv for First Solar Inc FS-6405: Voc=216.8 V, beta_Voc=-0.28%/C, Isc=2.52 A, STC=405.0 W, Area=2.48 m2.

Result: 2 panels max on 600 V (476.1 V); 20 panels for 8 kW (534 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6405?

Official CEC datasheet figures for First Solar Inc FS-6405 (CdTe) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6405.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 377.5 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 216.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 177.2 V / 2.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.28 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.33% (2.48 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6405 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6405 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 400 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 534 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 667 sq ft $2,533 $4,283

How Many First Solar Inc FS-6405 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6405 (238.05 V at 14 F).

Computed from Voc=216.8V and beta_Voc=-0.28%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 244.12 V 2 panels 488.2 V 4 panels
-10 C (14 F) 238.05 V 2 panels 476.1 V 4 panels
0 C (32 F) 231.98 V 2 panels 464.0 V 4 panels
25 C (77 F STC) 216.8 V 2 panels 433.6 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6405?

Competing CEC solar panels closest to First Solar Inc FS-6405 in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Single Junction Version 10
Applied Materials
414.0 W +9.0 W 194.2 V 7.24% 92.9%
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W +5.0 W 52.7 V 21.03% 94.1%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6405?

Evaluate First Solar Inc FS-6405 (405.0 W STC, 216.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6405 reaches 244.12 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 534 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (534 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6405 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6405 8 kW Residential Fit

Needs 20 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 377.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6405 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6405?

Multiplying First Solar Inc FS-6405's 2.52 A short-circuit current by 1.56 equals 3.93 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-6405 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 238.05 V cold Voc at 14 F and handles 2.52 A Isc; string inverters cap First Solar Inc FS-6405 at 2 panels on 600 V.

Is First Solar Inc FS-6405 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6405 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.