Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-6405-P — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6405-P is a 405.0 W STC (378.9 W PTC) CdTe solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 16.07% efficiency, 216.8 V Voc at 25 C, and 237.36 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
378.9 W
Voc @ 25C
216.8 V
Efficiency
16.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6405-P Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-6405-P (405.0 W STC) vs. Applied Materials Full Size Single Junction Version 10 across 131 CEC CdTe solar modules.

Built with 264 CdTe cells, First Solar Inc FS-6405-P pairs strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677) with 216.8 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,578 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Applied Materials Full Size Single Junction Version 10 offers a 414.0 W alternative.

Where Does First Solar Inc FS-6405-P Fall Across Listed CEC Models?

Plots First Solar Inc FS-6405-P at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6405-P (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 405.0 W

What Dataset Percentiles Define First Solar Inc FS-6405-P?

Benchmarks First Solar Inc FS-6405-P on STC wattage, thermal PTC/STC retention, and 16.07 aperture conversion efficiency against CEC peers.

First Solar Inc FS-6405-P Engineering BenchmarksPercentile comparison of First Solar Inc FS-6405-P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention93.6%Module Efficiency16.07%

What Do the Dataset Ranks Show for First Solar Inc FS-6405-P?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-6405-P by First Solar Inc.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #18,013

16.07% Aperture Efficiency

Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 237.36 V at -10 C (474.7 V string) and 243.24 V at -20 C (2 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 50.4 m2 (543 sq ft) producing 7,578 W PTC; NEC 690.8 OCPD floor is 3.93 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 216.8 * (1 + (-0.271/100) * (-10 - 25)) = 237.36 V | OCPD = 1.56 * 2.52 = 3.93 A

Inputs from CEC Modules.csv for First Solar Inc FS-6405-P: Voc=216.8 V, beta_Voc=-0.271%/C, Isc=2.52 A, STC=405.0 W, Area=2.52 m2.

Result: 2 panels max on 600 V (474.7 V); 20 panels for 8 kW (543 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6405-P?

Laboratory test ratings recorded for First Solar Inc FS-6405-P (CdTe) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6405-P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 378.9 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 216.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 177.2 V / 2.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.07% (2.52 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6405-P Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (543 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-6405-P.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 407 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 543 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 678 sq ft $2,533 $4,283

How Many First Solar Inc FS-6405-P Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-6405-P (beta_Voc -0.271%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=216.8V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 243.24 V 2 panels 486.5 V 4 panels
-10 C (14 F) 237.36 V 2 panels 474.7 V 4 panels
0 C (32 F) 231.49 V 2 panels 463.0 V 4 panels
25 C (77 F STC) 216.8 V 2 panels 433.6 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6405-P?

Closest cross-brand CEC competitors to First Solar Inc FS-6405-P matched near 405.0 W STC and 216.8 V Voc, led by Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Single Junction Version 10
Applied Materials
414.0 W +9.0 W 194.2 V 7.24% 92.9%
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W +5.0 W 52.7 V 21.03% 94.1%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6405-P?

Evaluate First Solar Inc FS-6405-P (405.0 W STC, 216.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6405-P reaches 243.24 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6405-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6405-P 8 kW Residential Fit

Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6405-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6405-P?

Multiplying First Solar Inc FS-6405-P's 2.52 A short-circuit current by 1.56 equals 3.93 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can First Solar Inc FS-6405-P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 237.36 V cold Voc at 14 F and handles 2.52 A Isc; string inverters cap First Solar Inc FS-6405-P at 2 panels on 600 V.

Is First Solar Inc FS-6405-P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6405-P rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.