First Solar Inc FS-6405-P-I is a 405.0 W STC (378.9 W PTC) CdTe solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 16.07% efficiency, 216.8 V Voc at 25 C, and 237.36 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 378.9 W
- Voc @ 25C
- 216.8 V
- Efficiency
- 16.07%
How Does First Solar Inc FS-6405-P-I Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6405-P-I (CdTe) residential solar systems.
Homeowners evaluating First Solar Inc FS-6405-P-I need 15 panels for 6 kW or 20 panels (543 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.271%/C) pushes open-circuit voltage to 237.36 V at 14 F and 243.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-6405-P-I Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6405-P-I (405.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6405-P-I?
Relative ranking of First Solar Inc FS-6405-P-I across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6405-P-I?
Summary of First Solar Inc FS-6405-P-I output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.07% Aperture Efficiency
Power density 160.7 W/m2 (3.84 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 237.36 V at -10 C (474.7 V string) and 243.24 V at -20 C (2 max).
20 Panels = 8,100 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,578 W PTC; NEC 690.8 OCPD floor is 3.93 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 216.8 * (1 + (-0.271/100) * (-10 - 25)) = 237.36 V | OCPD = 1.56 * 2.52 = 3.93 A
Inputs from CEC Modules.csv for First Solar Inc FS-6405-P-I: Voc=216.8 V, beta_Voc=-0.271%/C, Isc=2.52 A, STC=405.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (474.7 V); 20 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6405-P-I?
Complete CEC test sheet for First Solar Inc FS-6405-P-I including Isc (2.52 A), Voc (216.8 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 378.9 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 216.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 177.2 V / 2.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.07% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6405-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6405-P-I.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 407 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 543 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 678 sq ft | $2,533 | $4,283 |
How Many First Solar Inc FS-6405-P-I Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6405-P-I (216.8 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 243.24 V | 2 panels | 486.5 V | 4 panels |
| -10 C (14 F) | 237.36 V | 2 panels | 474.7 V | 4 panels |
| 0 C (32 F) | 231.49 V | 2 panels | 463.0 V | 4 panels |
| 25 C (77 F STC) | 216.8 V | 2 panels | 433.6 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6405-P-I?
Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | +9.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | +5.0 W | 52.7 V | 21.03% | 94.1% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6405-P-I?
Evaluate First Solar Inc FS-6405-P-I (405.0 W STC, 216.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6405-P-I reaches 243.24 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6405-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6405-P-I 8 kW Residential Fit
Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6405-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6405-P-I PTC wattage (378.9 W) lower than STC (405.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 378.9 W PTC (93.6% retention) across First Solar Inc FS-6405-P-I's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6405-P-I on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 First Solar Inc FS-6405-P-I panels (543 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.
What is the 1,000 V commercial string limit for First Solar Inc FS-6405-P-I?
On 1,000 V commercial inverters at -10 C (237.36 V cold Voc), First Solar Inc FS-6405-P-I fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6405-P-I.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)