Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-6400A is a 400.0 W STC (375.2 W PTC) CdTe solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 16.13% efficiency, 216.1 V Voc at 25 C, and 237.05 V cold Voc at -10 C (2 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
375.2 W
Voc @ 25C
216.1 V
Efficiency
16.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-6400A Compare Against Peer CEC Listings?

Solar engineering breakdown for First Solar Inc FS-6400A: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 400.0 W STC and 375.2 W PTC, First Solar Inc FS-6400A sits +15.0 W vs all-CEC median (top 45.5%; higher than 54.5% of peers) among 21,677 listed modules. Power density reaches 161.3 W/m2 (3.78 percentage points below 19.91% CEC median). Higher 216.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Single Junction Version 10 rates 414.0 W.

Where Does First Solar Inc FS-6400A Fall Across Listed CEC Models?

Distribution marker showing First Solar Inc FS-6400A (400.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-6400A (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 400.0 W

What Dataset Percentiles Define First Solar Inc FS-6400A?

Dataset percentiles tracking First Solar Inc FS-6400A power output, thermal retention ratio, and aperture efficiency against 21,677 models.

First Solar Inc FS-6400A Engineering BenchmarksPercentile comparison of First Solar Inc FS-6400A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention93.8%Module Efficiency16.13%

What Do the Dataset Ranks Show for First Solar Inc FS-6400A?

Benchmark highlights for First Solar Inc FS-6400A covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #17,965

16.13% Aperture Efficiency

Power density 161.3 W/m2 (3.78 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

2 Panels Max @ -10 C (600 V)

Cold Voc reaches 237.05 V at -10 C (474.1 V string) and 243.04 V at -20 C (2 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 49.6 m2 (534 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 3.92 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 216.1 * (1 + (-0.277/100) * (-10 - 25)) = 237.05 V | OCPD = 1.56 * 2.51 = 3.92 A

Inputs from CEC Modules.csv for First Solar Inc FS-6400A: Voc=216.1 V, beta_Voc=-0.277%/C, Isc=2.51 A, STC=400.0 W, Area=2.48 m2.

Result: 2 panels max on 600 V (474.1 V); 20 panels for 8 kW (534 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-6400A?

Official CEC datasheet figures for First Solar Inc FS-6400A (CdTe) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-6400A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 375.2 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 216.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.51 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 176.1 V / 2.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.277 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.13% (2.48 m2) Array roof footprint density
Cell Count & Technology 264 cells (CdTe) Monofacial backsheet

How Many First Solar Inc FS-6400A Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many First Solar Inc FS-6400A modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 400 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 534 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 667 sq ft $2,503 $4,232

How Many First Solar Inc FS-6400A Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6400A (237.05 V at 14 F).

Computed from Voc=216.1V and beta_Voc=-0.277%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 243.04 V 2 panels 486.1 V 4 panels
-10 C (14 F) 237.05 V 2 panels 474.1 V 4 panels
0 C (32 F) 231.06 V 2 panels 462.1 V 4 panels
25 C (77 F STC) 216.1 V 2 panels 432.2 V 4 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6400A?

Competing CEC solar panels closest to First Solar Inc FS-6400A in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Applied Materials Full Size Single Junction Version 10
Applied Materials
414.0 W +14.0 W 194.2 V 7.24% 92.9%
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W +10.0 W 52.7 V 21.03% 94.1%
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6400A?

Evaluate First Solar Inc FS-6400A (400.0 W STC, 216.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6400A reaches 243.04 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 534 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (534 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6400A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-6400A 8 kW Residential Fit

Needs 20 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 375.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-6400A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-6400A panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-6400A cold Voc rises from 216.1 V to 237.05 V (beta_Voc -0.277%/C), capping a 600 V string at 2 panels (474.1 V).

How much roof area does an 8 kW array of First Solar Inc FS-6400A need?

An 8 kW DC system uses 20 First Solar Inc FS-6400A modules (8,000 W STC / 7,504 W PTC), covering roughly 534 sq ft and saving ~$2,002/yr at 18.54 c/kWh.

How does First Solar Inc FS-6400A compare against Applied Materials Full Size Single Junction Version 10?

First Solar Inc FS-6400A outputs 400.0 W STC (216.1 V Voc, rank #9,407 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.