First Solar Inc FS-6400A-P-x is a 400.0 W STC (367.3 W PTC) CdTe solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 15.87% efficiency, 216.1 V Voc at 25 C, and 237.43 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 400.0 W
- PTC Wattage
- 367.3 W
- Voc @ 25C
- 216.1 V
- Efficiency
- 15.87%
How Does First Solar Inc FS-6400A-P-x Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6400A-P-x handles rooftop heat (367.3 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, First Solar Inc FS-6400A-P-x exhibits 2.51 A short-circuit current, requiring a 3.92 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #9,407 of 21,677 (45.0 W below the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 50.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 216.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6400A-P-x Fall Across Listed CEC Models?
Where First Solar Inc FS-6400A-P-x (400.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6400A-P-x?
Percentile placement of First Solar Inc FS-6400A-P-x across power density (158.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6400A-P-x?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6400A-P-x specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Top 45.5% STC Output
400.0 W STC (+15.0 W vs all-CEC median) vs 445.0 W CdTe median.
15.87% Aperture Efficiency
Power density 158.7 W/m2 (4.04 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 237.43 V at -10 C (474.9 V string) and 243.52 V at -20 C (2 max).
20 Panels = 8,000 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,346 W PTC; NEC 690.8 OCPD floor is 3.92 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 216.1 * (1 + (-0.282/100) * (-10 - 25)) = 237.43 V | OCPD = 1.56 * 2.51 = 3.92 A
Inputs from CEC Modules.csv for First Solar Inc FS-6400A-P-x: Voc=216.1 V, beta_Voc=-0.282%/C, Isc=2.51 A, STC=400.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (474.9 V); 20 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6400A-P-x?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6400A-P-x.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 400.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 367.3 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 216.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 176.1 V / 2.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.87% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6400A-P-x Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6400A-P-x (400.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.0 kW | 407 sq ft | $1,502 | $2,539 |
| 8 kW Class | 20 | 8.0 kW | 543 sq ft | $2,002 | $3,386 |
| 10 kW Class | 25 | 10.0 kW | 678 sq ft | $2,503 | $4,232 |
How Many First Solar Inc FS-6400A-P-x Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6400A-P-x from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 243.52 V | 2 panels | 487.0 V | 4 panels |
| -10 C (14 F) | 237.43 V | 2 panels | 474.9 V | 4 panels |
| 0 C (32 F) | 231.34 V | 2 panels | 462.7 V | 4 panels |
| 25 C (77 F STC) | 216.1 V | 2 panels | 432.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6400A-P-x?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6400A-P-x (400.0 W), including Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | +14.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | +10.0 W | 52.7 V | 21.03% | 94.1% |
| Boviet Solar Technology Co Ltd BVM6612M-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-400-H Boviet Solar Technology Co Ltd |
400.0 W | Tie (0 W) | 49.2 V | 20.62% | 93.2% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6400A-P-x?
Evaluate First Solar Inc FS-6400A-P-x (400.0 W STC, 216.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6400A-P-x reaches 243.52 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6400A-P-x carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6400A-P-x 8 kW Residential Fit
Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 367.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6400A-P-x by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6400A-P-x PTC wattage (367.3 W) lower than STC (400.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 367.3 W PTC (91.8% retention) across First Solar Inc FS-6400A-P-x's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6400A-P-x on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 First Solar Inc FS-6400A-P-x panels (543 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.
What is the 1,000 V commercial string limit for First Solar Inc FS-6400A-P-x?
On 1,000 V commercial inverters at -10 C (237.43 V cold Voc), First Solar Inc FS-6400A-P-x fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6400A-P-x.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)