Chinaland Solar Energy HSE260-60P is a 260.0 W STC (230.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.01% efficiency, 36.7 V Voc at 25 C, and 41.39 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 230.4 W
- Voc @ 25C
- 36.7 V
- Efficiency
- 16.01%
How Does Chinaland Solar Energy HSE260-60P Compare Against Peer CEC Listings?
Solar engineering breakdown for Chinaland Solar Energy HSE260-60P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Chinaland Solar Energy and peers, Chinaland Solar Energy HSE260-60P stands 18.8 W below the 278.8 W Multi-c-Si median and typical 88.6% PTC-to-STC thermal output (230.4 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Lower 36.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Chinaland Solar Energy HSE260-60P Fall Across Listed CEC Models?
Distribution marker showing Chinaland Solar Energy HSE260-60P (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Chinaland Solar Energy HSE260-60P?
Dataset percentiles tracking Chinaland Solar Energy HSE260-60P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Chinaland Solar Energy HSE260-60P?
Benchmark highlights for Chinaland Solar Energy HSE260-60P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.01% Aperture Efficiency
Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 88.6% (rank #21,091).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.39 V at -10 C (579.5 V string) and 42.73 V at -20 C (14 max).
31 Panels = 8,060 W STC
Occupies 50.3 m2 (542 sq ft) producing 7,142 W PTC; NEC 690.8 OCPD floor is 13.87 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.7 * (1 + (-0.365/100) * (-10 - 25)) = 41.39 V | OCPD = 1.56 * 8.89 = 13.87 A
Inputs from CEC Modules.csv for Chinaland Solar Energy HSE260-60P: Voc=36.7 V, beta_Voc=-0.365%/C, Isc=8.89 A, STC=260.0 W, Area=1.624 m2.
Result: 14 panels max on 600 V (579.5 V); 31 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for Chinaland Solar Energy HSE260-60P?
Official CEC datasheet figures for Chinaland Solar Energy HSE260-60P (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 230.4 W (88.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.89 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.9 V / 8.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.365 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.01% (1.624 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Chinaland Solar Energy HSE260-60P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Chinaland Solar Energy HSE260-60P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 682 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Chinaland Solar Energy Series?
Consolidated Chinaland Solar Energy wattage variants sharing the Chinaland Solar Energy HSE260-60P mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE250-60P | 250.0 W | 221.2 W | 36.3 V | 30.6 V | 15.4% |
| Chinaland Solar Energy HSE255-60P | 255.0 W | 225.8 W | 36.4 V | 30.7 V | 15.71% |
| Chinaland Solar Energy HSE260-60P | 260.0 W | 230.4 W | 36.7 V | 30.9 V | 16.01% |
| Chinaland Solar Energy HSE265-60P | 265.0 W | 234.9 W | 37.0 V | 31.0 V | 16.32% |
| Chinaland Solar Energy HSE270-60P | 270.0 W | 239.5 W | 37.2 V | 31.2 V | 16.63% |
How Many Chinaland Solar Energy HSE260-60P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Chinaland Solar Energy HSE260-60P (41.39 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.73 V | 14 panels | 598.2 V | 23 panels |
| -10 C (14 F) | 41.39 V | 14 panels | 579.5 V | 24 panels |
| 0 C (32 F) | 40.05 V | 14 panels | 560.7 V | 24 panels |
| 25 C (77 F STC) | 36.7 V | 16 panels | 587.2 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Chinaland Solar Energy HSE260-60P?
Competing CEC solar panels closest to Chinaland Solar Energy HSE260-60P in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJM260-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM260-60 Anhui Rinengzhongtian Semiconductor Development |
260.0 W | Tie (0 W) | 37.39 V | 15.98% | 90.2% |
| Gintung Energy ASEC-260G6S6A Gintung Energy |
260.0 W | Tie (0 W) | 37.42 V | 16.14% | 87.7% |
| CSI Solar Co Ltd CS6P-260P CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
| CSI Solar Co Ltd CS6P-260PX CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.5 V | 16.79% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Chinaland Solar Energy HSE260-60P?
Evaluate Chinaland Solar Energy HSE260-60P (260.0 W STC, 36.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chinaland Solar Energy HSE260-60P reaches 42.73 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of Chinaland Solar Energy HSE260-60P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chinaland Solar Energy HSE260-60P 8 kW Residential Fit
Needs 31 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM260-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 230.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chinaland Solar Energy HSE260-60P by Chinaland Solar Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Chinaland Solar Energy HSE260-60P?
Multiplying Chinaland Solar Energy HSE260-60P's 8.89 A short-circuit current by 1.56 equals 13.87 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Chinaland Solar Energy HSE260-60P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.39 V cold Voc at 14 F and handles 8.89 A Isc; string inverters cap Chinaland Solar Energy HSE260-60P at 14 panels on 600 V.
Is Chinaland Solar Energy HSE260-60P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Chinaland Solar Energy HSE260-60P rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)