AXITEC AC-320P/72XV is a 320.0 W STC (290.2 W PTC) Multi-c-Si solar module ranking #14,944 of 21,677 CEC listings (below all-CEC median; higher than 29.0% of peers). It delivers 16.58% efficiency, 45.82 V Voc at 25 C, and 50.95 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 320.0 W
- PTC Wattage
- 290.2 W
- Voc @ 25C
- 45.82 V
- Efficiency
- 16.58%
How Does AXITEC AC-320P/72XV Compare Against Peer CEC Listings?
How AXITEC AXITEC AC-320P/72XV handles rooftop heat (290.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, AXITEC AC-320P/72XV exhibits 9.03 A short-circuit current, requiring a 14.09 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #14,944 of 21,677 (41.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 48.2 m2 for an 8 kW system (32 panels for 10 kW). Mid-range 45.82 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does AXITEC AC-320P/72XV Fall Across Listed CEC Models?
Where AXITEC AC-320P/72XV (320.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-320P/72XV?
Percentile placement of AXITEC AC-320P/72XV across power density (165.8 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for AXITEC AC-320P/72XV?
Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-320P/72XV specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
320.0 W STC · Higher Than 29.0%
320.0 W STC (-65.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.58% Aperture Efficiency
Power density 165.8 W/m2 (3.33 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.95 V at -10 C (560.5 V string) and 52.42 V at -20 C (11 max).
25 Panels = 8,000 W STC
Occupies 48.2 m2 (519 sq ft) producing 7,255 W PTC; NEC 690.8 OCPD floor is 14.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.82 * (1 + (-0.32/100) * (-10 - 25)) = 50.95 V | OCPD = 1.56 * 9.03 = 14.09 A
Inputs from CEC Modules.csv for AXITEC AC-320P/72XV: Voc=45.82 V, beta_Voc=-0.32%/C, Isc=9.03 A, STC=320.0 W, Area=1.93 m2.
Result: 11 panels max on 600 V (560.5 V); 25 panels for 8 kW (519 sq ft).
What Are the Published CEC Specifications for AXITEC AC-320P/72XV?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-320P/72XV.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 320.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 290.2 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.82 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.03 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.56 V / 8.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.58% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many AXITEC AC-320P/72XV Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-320P/72XV (320.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.08 kW | 395 sq ft | $1,522 | $2,573 |
| 8 kW Class | 25 | 8.0 kW | 519 sq ft | $2,002 | $3,386 |
| 10 kW Class | 32 | 10.24 kW | 665 sq ft | $2,563 | $4,334 |
How Many AXITEC AC-320P/72XV Modules Fit in a Cold-Weather String?
Maximum series module counts for AXITEC AC-320P/72XV from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.42 V | 11 panels | 576.6 V | 19 panels |
| -10 C (14 F) | 50.95 V | 11 panels | 560.5 V | 19 panels |
| 0 C (32 F) | 49.49 V | 12 panels | 593.9 V | 20 panels |
| 25 C (77 F STC) | 45.82 V | 13 panels | 595.7 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-320P/72XV?
Alternative CEC solar modules from competing brands near AXITEC AC-320P/72XV (320.0 W), including GCL System Integration Technology Co Ltd GCL-P6/72320.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-P6/72320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 45.8 V | 16.49% | 90.6% |
| GCL System Integration Technology Co Ltd GCL-P6/72B320 GCL System Integration Technology Co Ltd |
320.0 W | Tie (0 W) | 45.8 V | 16.49% | 90.2% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
320.0 W | Tie (0 W) | 45.94 V | 16.64% | 91.2% |
| CertainTeed CT320P00-01 CertainTeed |
320.0 W | Tie (0 W) | 45.7 V | 17.68% | 91.8% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-320P/72XV?
Evaluate AXITEC AC-320P/72XV (320.0 W STC, 45.82 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-320P/72XV reaches 52.42 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 519 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (519 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-320P/72XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-320P/72XV 8 kW Residential Fit
Needs 25 modules (519 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/72320.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 290.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-320P/72XV by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AXITEC AC-320P/72XV PTC wattage (290.2 W) lower than STC (320.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 290.2 W PTC (90.7% retention) across AXITEC AC-320P/72XV's 1.93 m2 aperture.
Who should skip AXITEC AC-320P/72XV on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 AXITEC AC-320P/72XV panels (519 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-P6/72320.
What is the 1,000 V commercial string limit for AXITEC AC-320P/72XV?
On 1,000 V commercial inverters at -10 C (50.95 V cold Voc), AXITEC AC-320P/72XV fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-320P/72XV.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)