Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M395B is a 395.0 W STC (371.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.84% efficiency, 37.03 V Voc at 25 C, and 40.19 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
371.0 W
Voc @ 25C
37.03 V
Efficiency
20.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M395B Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN10M395B (395.0 W STC) vs. Convalt Manufacturing LLC CVLT395-108M-BB across 5,889 CEC Mono-c-Si solar modules.

Ranking #9,869 across 21,677 CEC solar panels (top 47.6%; higher than 52.4% of peers), Auxin Solar AXN10M395B operates as a modern high-density residential and light-commercial module sitting 15.0 W below the 410.0 W Mono-c-Si median. Lower 37.03 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), 21 panels occupy 428 sq ft and offset roughly $2,075/yr at average US rates (or $3,509/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN10M395B Fall Across Listed CEC Models?

Plots Auxin Solar AXN10M395B at 395.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M395B (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 395.0 W

What Dataset Percentiles Define Auxin Solar AXN10M395B?

Benchmarks Auxin Solar AXN10M395B on STC wattage, thermal PTC/STC retention, and 20.84 aperture conversion efficiency against CEC peers.

Auxin Solar AXN10M395B Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M395B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.9%Module Efficiency20.84%

What Do the Dataset Ranks Show for Auxin Solar AXN10M395B?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN10M395B by Auxin Solar.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,089

20.84% Aperture Efficiency

Power density 208.4 W/m2 (0.93 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.19 V at -10 C (562.7 V string) and 41.1 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,791 W PTC; NEC 690.8 OCPD floor is 21.2 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.03 * (1 + (-0.244/100) * (-10 - 25)) = 40.19 V | OCPD = 1.56 * 13.59 = 21.2 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M395B: Voc=37.03 V, beta_Voc=-0.244%/C, Isc=13.59 A, STC=395.0 W, Area=1.895 m2.

Result: 14 panels max on 600 V (562.7 V); 21 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M395B?

Laboratory test ratings recorded for Auxin Solar AXN10M395B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M395B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 371.0 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.03 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.0 V / 12.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.244 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.84% (1.895 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M395B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (428 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN10M395B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 326 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 428 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 530 sq ft $2,570 $4,347

How Many Auxin Solar AXN10M395B Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN10M395B (beta_Voc -0.244%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.03V and beta_Voc=-0.244%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.1 V 14 panels 575.4 V 24 panels
-10 C (14 F) 40.19 V 14 panels 562.7 V 24 panels
0 C (32 F) 39.29 V 15 panels 589.4 V 25 panels
25 C (77 F STC) 37.03 V 16 panels 592.5 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M395B?

Closest cross-brand CEC competitors to Auxin Solar AXN10M395B matched near 395.0 W STC and 37.03 V Voc, led by Convalt Manufacturing LLC CVLT395-108M-BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Convalt Manufacturing LLC CVLT395-108M-BB
Convalt Manufacturing LLC
395.0 W Tie (0 W) 37.03 V 20.36% 91.9%
Elin Energy (Sirius PV) ELNSM54M-HC-395
Elin Energy (Sirius PV)
395.0 W Tie (0 W) 37.02 V 20.36% 94.2%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-395
Elin Energy (Sirius PV)
395.0 W Tie (0 W) 37.02 V 20.36% 94.2%
Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
395.0 W Tie (0 W) 37.0 V 20.26% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M395B?

Evaluate Auxin Solar AXN10M395B (395.0 W STC, 37.03 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M395B reaches 41.1 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (428 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M395B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M395B 8 kW Residential Fit

Needs 21 modules (428 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Convalt Manufacturing LLC CVLT395-108M-BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 371.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M395B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN10M395B panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN10M395B cold Voc rises from 37.03 V to 40.19 V (beta_Voc -0.244%/C), capping a 600 V string at 14 panels (562.7 V).

How much roof area does an 8 kW array of Auxin Solar AXN10M395B need?

An 8 kW DC system uses 21 Auxin Solar AXN10M395B modules (8,295 W STC / 7,791 W PTC), covering roughly 428 sq ft and saving ~$2,075/yr at 18.54 c/kWh.

How does Auxin Solar AXN10M395B compare against Convalt Manufacturing LLC CVLT395-108M-BB?

Auxin Solar AXN10M395B outputs 395.0 W STC (37.03 V Voc, rank #9,869 of 21,677), while Convalt Manufacturing LLC CVLT395-108M-BB delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.