Skip to main content
WireAndSun
Calculators
CEC PV Module

AMPS Solar AMPS-450N-108BB — CEC Solar Module Specifications

Manufacturer: AMPS Solar Registry: CEC Verified Engineering Specification

AMPS Solar AMPS-450N-108BB is a 450.0 W STC (428.2 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.2% efficiency, 40.16 V Voc at 25 C, and 43.41 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
428.2 W
Voc @ 25C
40.16 V
Efficiency
23.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AMPS Solar AMPS-450N-108BB Compare Against Peer CEC Listings?

Solar engineering breakdown for AMPS Solar AMPS-450N-108BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Measured at 450.0 W STC and 428.2 W PTC, AMPS Solar AMPS-450N-108BB sits +65.0 W vs all-CEC median (top 27.8%; higher than 72.2% of peers) among 21,677 listed modules. Power density reaches 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). Mid-range 40.16 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer ES Foundry Corp ES-DN8-H54B-450 rates 450.0 W.

Where Does AMPS Solar AMPS-450N-108BB Fall Across Listed CEC Models?

Distribution marker showing AMPS Solar AMPS-450N-108BB (450.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AMPS Solar AMPS-450N-108BB (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAMPS Solar AMPS-45: 450.0 W

What Dataset Percentiles Define AMPS Solar AMPS-450N-108BB?

Dataset percentiles tracking AMPS Solar AMPS-450N-108BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AMPS Solar AMPS-450N-108BB Engineering BenchmarksPercentile comparison of AMPS Solar AMPS-450N-108BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention95.2%Module Efficiency23.2%

What Do the Dataset Ranks Show for AMPS Solar AMPS-450N-108BB?

Benchmark highlights for AMPS Solar AMPS-450N-108BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #871

23.2% Aperture Efficiency

Power density 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.41 V at -10 C (564.3 V string) and 44.33 V at -20 C (13 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 34.9 m2 (376 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.16 * (1 + (-0.231/100) * (-10 - 25)) = 43.41 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for AMPS Solar AMPS-450N-108BB: Voc=40.16 V, beta_Voc=-0.231%/C, Isc=14.19 A, STC=450.0 W, Area=1.94 m2.

Result: 13 panels max on 600 V (564.3 V); 18 panels for 8 kW (376 sq ft).

What Are the Published CEC Specifications for AMPS Solar AMPS-450N-108BB?

Official CEC datasheet figures for AMPS Solar AMPS-450N-108BB (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for AMPS Solar AMPS-450N-108BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 428.2 W (95.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.16 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.03 V / 13.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.231 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.2% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Bifacial glass-glass

How Many AMPS Solar AMPS-450N-108BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AMPS Solar AMPS-450N-108BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 292 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 376 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 480 sq ft $2,591 $4,380

How Many AMPS Solar AMPS-450N-108BB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AMPS Solar AMPS-450N-108BB (43.41 V at 14 F).

Computed from Voc=40.16V and beta_Voc=-0.231%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.33 V 13 panels 576.3 V 22 panels
-10 C (14 F) 43.41 V 13 panels 564.3 V 23 panels
0 C (32 F) 42.48 V 14 panels 594.7 V 23 panels
25 C (77 F STC) 40.16 V 14 panels 562.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-450N-108BB?

Competing CEC solar panels closest to AMPS Solar AMPS-450N-108BB in nameplate wattage and Voc, starting with ES Foundry Corp ES-DN8-H54B-450.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ES Foundry Corp ES-DN8-H54B-450
ES Foundry Corp
450.0 W Tie (0 W) 39.54 V 23.11% 95.2%
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10
CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET
450.0 W Tie (0 W) 39.53 V 23.08% 96.1%
Aptos Solar Technology LLC DNA-108-BFN10-455W-DG
Aptos Solar Technology LLC
455.0 W +5.0 W 39.7 V 23.45% 95.1%
CertainTeed CTTC455HC12-08
CertainTeed
455.0 W +5.0 W 39.0 V 23.33% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-450N-108BB?

Evaluate AMPS Solar AMPS-450N-108BB (450.0 W STC, 40.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-450N-108BB reaches 44.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-450N-108BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AMPS Solar AMPS-450N-108BB 8 kW Residential Fit

Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ES Foundry Corp ES-DN8-H54B-450.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 428.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AMPS Solar AMPS-450N-108BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many AMPS Solar AMPS-450N-108BB panels fit on a 600 V winter solar string?

At -10 C (14 F), AMPS Solar AMPS-450N-108BB cold Voc rises from 40.16 V to 43.41 V (beta_Voc -0.231%/C), capping a 600 V string at 13 panels (564.3 V).

How much roof area does an 8 kW array of AMPS Solar AMPS-450N-108BB need?

An 8 kW DC system uses 18 AMPS Solar AMPS-450N-108BB modules (8,100 W STC / 7,708 W PTC), covering roughly 376 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does AMPS Solar AMPS-450N-108BB compare against ES Foundry Corp ES-DN8-H54B-450?

AMPS Solar AMPS-450N-108BB outputs 450.0 W STC (40.16 V Voc, rank #5,679 of 21,677), while ES Foundry Corp ES-DN8-H54B-450 delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.