AMPS Solar AMPS-450N-108BB is a 450.0 W STC (428.2 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 23.2% efficiency, 40.16 V Voc at 25 C, and 43.41 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 450.0 W
- PTC Wattage
- 428.2 W
- Voc @ 25C
- 40.16 V
- Efficiency
- 23.2%
How Does AMPS Solar AMPS-450N-108BB Compare Against Peer CEC Listings?
Solar engineering breakdown for AMPS Solar AMPS-450N-108BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
Measured at 450.0 W STC and 428.2 W PTC, AMPS Solar AMPS-450N-108BB sits +65.0 W vs all-CEC median (top 27.8%; higher than 72.2% of peers) among 21,677 listed modules. Power density reaches 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). Mid-range 40.16 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 23 panels in series. Alternative peer ES Foundry Corp ES-DN8-H54B-450 rates 450.0 W.
Where Does AMPS Solar AMPS-450N-108BB Fall Across Listed CEC Models?
Distribution marker showing AMPS Solar AMPS-450N-108BB (450.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define AMPS Solar AMPS-450N-108BB?
Dataset percentiles tracking AMPS Solar AMPS-450N-108BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for AMPS Solar AMPS-450N-108BB?
Benchmark highlights for AMPS Solar AMPS-450N-108BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Top 27.8% STC Output
450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.2% Aperture Efficiency
Power density 232.0 W/m2 (3.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.41 V at -10 C (564.3 V string) and 44.33 V at -20 C (13 max).
18 Panels = 8,100 W STC
Occupies 34.9 m2 (376 sq ft) producing 7,708 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.16 * (1 + (-0.231/100) * (-10 - 25)) = 43.41 V | OCPD = 1.56 * 14.19 = 22.14 A
Inputs from CEC Modules.csv for AMPS Solar AMPS-450N-108BB: Voc=40.16 V, beta_Voc=-0.231%/C, Isc=14.19 A, STC=450.0 W, Area=1.94 m2.
Result: 13 panels max on 600 V (564.3 V); 18 panels for 8 kW (376 sq ft).
What Are the Published CEC Specifications for AMPS Solar AMPS-450N-108BB?
Official CEC datasheet figures for AMPS Solar AMPS-450N-108BB (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 450.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 428.2 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.16 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.03 V / 13.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.231 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.2% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many AMPS Solar AMPS-450N-108BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AMPS Solar AMPS-450N-108BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.3 kW | 292 sq ft | $1,577 | $2,666 |
| 8 kW Class | 18 | 8.1 kW | 376 sq ft | $2,027 | $3,428 |
| 10 kW Class | 23 | 10.35 kW | 480 sq ft | $2,591 | $4,380 |
How Many AMPS Solar AMPS-450N-108BB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AMPS Solar AMPS-450N-108BB (43.41 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.33 V | 13 panels | 576.3 V | 22 panels |
| -10 C (14 F) | 43.41 V | 13 panels | 564.3 V | 23 panels |
| 0 C (32 F) | 42.48 V | 14 panels | 594.7 V | 23 panels |
| 25 C (77 F STC) | 40.16 V | 14 panels | 562.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to AMPS Solar AMPS-450N-108BB?
Competing CEC solar panels closest to AMPS Solar AMPS-450N-108BB in nameplate wattage and Voc, starting with ES Foundry Corp ES-DN8-H54B-450.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ES Foundry Corp ES-DN8-H54B-450 ES Foundry Corp |
450.0 W | Tie (0 W) | 39.54 V | 23.11% | 95.2% |
| CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10 CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET |
450.0 W | Tie (0 W) | 39.53 V | 23.08% | 96.1% |
| Aptos Solar Technology LLC DNA-108-BFN10-455W-DG Aptos Solar Technology LLC |
455.0 W | +5.0 W | 39.7 V | 23.45% | 95.1% |
| CertainTeed CTTC455HC12-08 CertainTeed |
455.0 W | +5.0 W | 39.0 V | 23.33% | 94.9% |
What Are the Design Limits and Best-Fit Uses for AMPS Solar AMPS-450N-108BB?
Evaluate AMPS Solar AMPS-450N-108BB (450.0 W STC, 40.16 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AMPS Solar AMPS-450N-108BB reaches 44.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 376 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (376 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AMPS Solar AMPS-450N-108BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AMPS Solar AMPS-450N-108BB 8 kW Residential Fit
Needs 18 modules (376 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ES Foundry Corp ES-DN8-H54B-450.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 428.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AMPS Solar AMPS-450N-108BB by AMPS Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many AMPS Solar AMPS-450N-108BB panels fit on a 600 V winter solar string?
At -10 C (14 F), AMPS Solar AMPS-450N-108BB cold Voc rises from 40.16 V to 43.41 V (beta_Voc -0.231%/C), capping a 600 V string at 13 panels (564.3 V).
How much roof area does an 8 kW array of AMPS Solar AMPS-450N-108BB need?
An 8 kW DC system uses 18 AMPS Solar AMPS-450N-108BB modules (8,100 W STC / 7,708 W PTC), covering roughly 376 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does AMPS Solar AMPS-450N-108BB compare against ES Foundry Corp ES-DN8-H54B-450?
AMPS Solar AMPS-450N-108BB outputs 450.0 W STC (40.16 V Voc, rank #5,679 of 21,677), while ES Foundry Corp ES-DN8-H54B-450 delivers 450.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)