Univix Power Solutions: UVX6KLNA {240V} outputs 6,000 W AC at 240 V (25.0 A continuous, 35 A OCPD), ranking #822 of 2,343 CEC inverters at 97.15% efficiency with a 200-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 6,000 W
- AC Voltage
- 240 V
- Min PV Breaker
- 35 A (8 AWG Cu)
- CEC Efficiency
- 97.15%
How Does Univix Power Solutions: UVX6KLNA {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#822), 200-430 V MPPT tracking, and panel fit for Univix Power Solutions: UVX6KLNA {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Univix Power Solutions: UVX6KLNA {240V} from Univix Power Solutions outputs 25.0 A continuous AC at 240 V (6,000 W AC, rank #1,387). Paired with 8 AWG Cu conductors and a 35 A OCPD, its 97.15% CEC efficiency compares closely with ABB: PVI-6000-OUTD-US-A {240V} (6,000 W). Keep NEC 690.7 winter string Voc below 430 V DC.
Where Does Univix Power Solutions: UVX6KLNA {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Univix Power Solutions: UVX6KLNA {240V} at 6,000 W continuous AC output. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define Univix Power Solutions: UVX6KLNA {240V}?
Dataset percentiles comparing Univix Power Solutions: UVX6KLNA {240V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Univix Power Solutions: UVX6KLNA {240V}?
Engineering highlights for Univix Power Solutions: UVX6KLNA {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
97.15% CEC Weighted Efficiency
+0.47 pts vs the 96.68% 240 V median; overall power rank #1,387 (6,000 W, below CEC median; higher than 39.4% of peers).
35 A Required Backfeed OCPD
125% x 25.0 A = 31.2 A -> 35 A standard OCPD using 8 AWG Cu (75 C).
200 V - 430 V (Max 430 V DC)
Tracking span of 230.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 6000.0W / 240 V -> 25.0 A | Breaker >= 1.25 * 25.0 = 31.2 A -> 35 A
CEC Inverters.csv for Univix Power Solutions: UVX6KLNA {240V}: Paco=6000.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.15%.
Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Univix Power Solutions: UVX6KLNA {240V}?
California Energy Commission Solar Equipment List parameters for Univix Power Solutions: UVX6KLNA {240V} (hybrid battery-capable inverter) interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 6,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 200 V - 430 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 17.1554 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.15% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Univix Power Solutions: UVX6KLNA {240V}?
Panelboard and switchgear backfeed allowances for Univix Power Solutions: UVX6KLNA {240V} (35 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 35 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 35 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 35 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 35 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 35 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Univix Power Solutions: UVX6KLNA {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Univix Power Solutions: UVX6KLNA {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 7 panels | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 6 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 6 to 9 panels | 3.83 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 7 to 10 panels | 2.0 kW |
Which Competing Grid-Support Inverters Compare to Univix Power Solutions: UVX6KLNA {240V}?
Four alternative CEC inverters matched to Univix Power Solutions: UVX6KLNA {240V} (6,000 W AC), led by ABB: PVI-6000-OUTD-US-A {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: PVI-6000-OUTD-US-A {240V} ABB |
6,000 W | Tie (0 W) | 240.0 V | 480.0 V | 96.21% |
| ABB: PVI-6000-OUTD-US-Z-A {240V} ABB |
6,000 W | Tie (0 W) | 240.0 V | 480.0 V | 96.21% |
| ABB: PVI-6000-OUTD-US-Z-M-A {240V} ABB |
6,000 W | Tie (0 W) | 240.0 V | 480.0 V | 96.21% |
| ABB: UNO-DM-60-TL-PLUS-US-S-XRA {240V} ABB |
6,000 W | Tie (0 W) | 240.0 V | 480.0 V | 97.03% |
What Are the Interconnection Limits and Best-Fit Uses for Univix Power Solutions: UVX6KLNA {240V}?
Check Univix Power Solutions: UVX6KLNA {240V} (6,000 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Univix Power Solutions: UVX6KLNA {240V}.
Univix Power Solutions: UVX6KLNA {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (25.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.15%) and MPPT window (200-430 V) directly against ABB: PVI-6000-OUTD-US-A {240V} (6,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Univix Power Solutions: UVX6KLNA {240V} by Univix Power Solutions covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Univix Power Solutions: UVX6KLNA {240V} require?
At 6,000 W continuous AC (240 V), continuous current is 25.0 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.
Does Univix Power Solutions: UVX6KLNA {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).
How does Univix Power Solutions: UVX6KLNA {240V} compare to ABB: PVI-6000-OUTD-US-A {240V}?
Univix Power Solutions: UVX6KLNA {240V} delivers 6,000 W AC at 97.15% CEC efficiency with a 430 V DC ceiling, while ABB: PVI-6000-OUTD-US-A {240V} outputs 6,000 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)