Univix Power Solutions: UVX10KLNA {240V} — CEC Inverter Specifications

Manufacturer: Univix Power Solutions Registry: CEC Verified Engineering Specification

Univix Power Solutions: UVX10KLNA {240V} outputs 10,000 W AC at 240 V (41.7 A continuous, 60 A OCPD), ranking #808 of 2,343 CEC inverters at 97.16% efficiency with a 280-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,000 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Univix Power Solutions: UVX10KLNA {240V} Compare Against Peer CEC Listings?

Breaker sizing (60 A), 6 AWG Cu wire rules, and DC input limits for Univix Power Solutions: UVX10KLNA {240V}.

For NEC 705.12 solar interconnection, Univix Power Solutions: UVX10KLNA {240V} outputs 41.7 A continuous AC at 240 V and needs a 60 A backfeed breaker on 6 AWG Cu (75 C). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Conversion efficiency scores 97.16% (#808 of 2,343, +0.34 pts vs overall CEC median).

Where Does Univix Power Solutions: UVX10KLNA {240V} Fall Across Listed CEC Models?

Output power comparison showing where Univix Power Solutions: UVX10KLNA {240V} sits among all 2,343 CEC-listed grid-support inverters. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Univix Power Solutions: UVX10KLNA {240V} (10,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACUnivix Power Solut: 10,000 W

What Dataset Percentiles Define Univix Power Solutions: UVX10KLNA {240V}?

Relative ranking of Univix Power Solutions: UVX10KLNA {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Univix Power Solutions: UVX10KLNA {240V} Technical ThresholdsPercentile comparison for Univix Power Solutions: UVX10KLNA {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,000 WCEC Efficiency97.16%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Univix Power Solutions: UVX10KLNA {240V}?

Snapshot of Univix Power Solutions: UVX10KLNA {240V} efficiency rank (#808), OCPD breaker size, MPPT span, and busbar verdict.

Eff #808 / 2,343

97.16% CEC Weighted Efficiency

+0.48 pts vs the 96.68% 240 V median; overall power rank #909 (10,000 W, top 38.9%; higher than 61.1% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 41.7 A = 52.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

280 V - 430 V (Max 430 V DC)

Tracking span of 150.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10000.0W / 240 V -> 41.7 A | Breaker >= 1.25 * 41.7 = 52.1 A -> 60 A

CEC Inverters.csv for Univix Power Solutions: UVX10KLNA {240V}: Paco=10000.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=97.16%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Univix Power Solutions: UVX10KLNA {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Univix Power Solutions: UVX10KLNA {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Univix Power Solutions: UVX10KLNA {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 430 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 280 V - 430 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 28.5888 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.16% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Univix Power Solutions: UVX10KLNA {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Univix Power Solutions: UVX10KLNA {240V} at 240 V. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates Univix Power Solutions: UVX10KLNA {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Univix Power Solutions: UVX10KLNA {240V}?

Minimum and maximum series solar module strings fitting Univix Power Solutions: UVX10KLNA {240V} MPPT and 430 V limits.

Sampled CEC PV modules aligned within 280.0-430.0 V MPPT and 430.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 panels (fixed) 4.13 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 9 panels (fixed) 3.83 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 10 panels (fixed) 2.0 kW

Which Competing Grid-Support Inverters Compare to Univix Power Solutions: UVX10KLNA {240V}?

Peer 240 V CEC inverters near 10,000 W AC output such as Base Power Inc: MIN 10000TL-XH-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Base Power Inc: MIN 10000TL-XH-US {240V}
Base Power Inc
10,082 W +82 W 240.0 V 480.0 V 97.61%
Amensolar Ess Co Ltd: N3H-X100-US {240V}
Amensolar Ess Co Ltd
10,177 W +177 W 240.0 V 430.0 V 97.15%
Amensolar Ess Co Ltd: N3H-X10US {240V}
Amensolar Ess Co Ltd
10,177 W +177 W 240.0 V 430.0 V 97.15%
Delta Electronics: E10_BDI {240V}
Delta Electronics
9,674 W -326 W 240.0 V 480.0 V 97.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Univix Power Solutions: UVX10KLNA {240V}?

Check Univix Power Solutions: UVX10KLNA {240V} (10,000 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Univix Power Solutions: UVX10KLNA {240V}.

Univix Power Solutions: UVX10KLNA {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (41.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.16%) and MPPT window (280-430 V) directly against Base Power Inc: MIN 10000TL-XH-US {240V} (10,082 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Univix Power Solutions: UVX10KLNA {240V} by Univix Power Solutions covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Univix Power Solutions: UVX10KLNA {240V} require?

At 10,000 W continuous AC (240 V), continuous current is 41.7 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Univix Power Solutions: UVX10KLNA {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Univix Power Solutions: UVX10KLNA {240V} compare to Base Power Inc: MIN 10000TL-XH-US {240V}?

Univix Power Solutions: UVX10KLNA {240V} delivers 10,000 W AC at 97.16% CEC efficiency with a 430 V DC ceiling, while Base Power Inc: MIN 10000TL-XH-US {240V} outputs 10,082 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.