Univix Power Solutions: UVX16LNA {240V} outputs 16,000 W AC at 240 V (66.7 A continuous, 90 A OCPD), ranking #1,808 of 2,343 CEC inverters at 96.26% efficiency with a 220-430 V MPPT window and 430 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 16,000 W
- AC Voltage
- 240 V
- Min PV Breaker
- 90 A (3 AWG Cu)
- CEC Efficiency
- 96.26%
How Does Univix Power Solutions: UVX16LNA {240V} Compare Against Peer CEC Listings?
How Univix Power Solutions Univix Power Solutions: UVX16LNA {240V} compares on 96.26% efficiency, MPPT span, and 120% busbar interconnection.
With a 220-430 V MPPT tracking band and 430 V DC ceiling, Univix Power Solutions: UVX16LNA {240V} handles 16,000 W continuous AC (10,224 W above the 5,776 W 240 V median). Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Univix Power Solutions against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Univix Power Solutions: UVX16LNA {240V} Fall Across Listed CEC Models?
Position of Univix Power Solutions: UVX16LNA {240V} (16,000 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Univix Power Solutions: UVX16LNA {240V}?
Percentile placement of Univix Power Solutions: UVX16LNA {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Univix Power Solutions: UVX16LNA {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Univix Power Solutions: UVX16LNA {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
96.26% CEC Weighted Efficiency
-0.42 pts vs the 96.68% 240 V median; overall power rank #659 (16,000 W, top 28.1%; higher than 71.9% of peers).
90 A Required Backfeed OCPD
125% x 66.7 A = 83.4 A -> 90 A standard OCPD using 3 AWG Cu (75 C).
220 V - 430 V (Max 430 V DC)
Tracking span of 210.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 16000.0W / 240 V -> 66.7 A | Breaker >= 1.25 * 66.7 = 83.4 A -> 90 A
CEC Inverters.csv for Univix Power Solutions: UVX16LNA {240V}: Paco=16000.0 W, Vac=240 V, Vdcmax=430.0 V, Eff=96.26%.
Result: Min 90 A breaker & 3 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Univix Power Solutions: UVX16LNA {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Univix Power Solutions: UVX16LNA {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 16,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 430 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 220 V - 430 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 46.1701 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.26% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Univix Power Solutions: UVX16LNA {240V}?
Check whether Univix Power Solutions: UVX16LNA {240V} (90 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 90 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 90 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 90 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 90 A | Needs Derate / Tap 705.11 |
| 225A Bus / 200A Main | 70 A | 90 A | Needs Derate / Tap 705.11 |
Which CEC PV Module Strings Pair With Univix Power Solutions: UVX16LNA {240V}?
Verified cold-weather (-10 C) series module counts matched to Univix Power Solutions: UVX16LNA {240V}'s 430 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 7 panels | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 7 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 7 to 9 panels | 3.83 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 8 to 10 panels | 2.0 kW |
Which Competing Grid-Support Inverters Compare to Univix Power Solutions: UVX16LNA {240V}?
Alternative CEC inverters comparable to Univix Power Solutions: UVX16LNA {240V}, including Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Amensolar Ess Co Ltd: N3H-X16US {240V} Amensolar Ess Co Ltd |
16,199 W | +199 W | 240.0 V | 430.0 V | 96.25% |
| Amensolar Ess Co Ltd: N3H-X12US {240V} Amensolar Ess Co Ltd |
12,214 W | -3786 W | 240.0 V | 430.0 V | 96.17% |
| Chint Power Systems America: CPS ECH12KTL/US {240V} Chint Power Systems America |
11,990 W | -4010 W | 240.0 V | 480.0 V | 96.59% |
| Delta Electronics: S12_BDI {240V} Delta Electronics |
11,589 W | -4411 W | 240.0 V | 480.0 V | 96.99% |
What Are the Interconnection Limits and Best-Fit Uses for Univix Power Solutions: UVX16LNA {240V}?
Check Univix Power Solutions: UVX16LNA {240V} (16,000 W AC, 90 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 90 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 430 V DC on Univix Power Solutions: UVX16LNA {240V}.
Univix Power Solutions: UVX16LNA {240V} Panel & Wire Spec
Size 75 C copper conductors at 3 AWG Cu on a 90 A OCPD breaker (66.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.26%) and MPPT window (220-430 V) directly against Amensolar Ess Co Ltd: N3H-X16US {240V} (16,199 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Univix Power Solutions: UVX16LNA {240V} by Univix Power Solutions covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Univix Power Solutions: UVX16LNA {240V} require?
At 16,000 W continuous AC (240 V), continuous current is 66.7 A; 125% NEC 690.8/705.12 sizing requires a 90 A breaker and 3 AWG Cu (75 C) wire.
Does Univix Power Solutions: UVX16LNA {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 90 A at 240 V means Needs Derate / Tap 705.11.
How does Univix Power Solutions: UVX16LNA {240V} compare to Amensolar Ess Co Ltd: N3H-X16US {240V}?
Univix Power Solutions: UVX16LNA {240V} delivers 16,000 W AC at 96.26% CEC efficiency with a 430 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X16US {240V} outputs 16,199 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)