Tigo Energy Inc: TSI-30K-US {208V} outputs 2,626 W AC at 208 V, commercial single-phase (12.6 A continuous, 20 A OCPD), ranking #1,217 of 2,343 CEC inverters at 96.77% efficiency with a 125-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,626 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 20 A (12 AWG Cu)
- CEC Efficiency
- 96.77%
How Does Tigo Energy Inc: TSI-30K-US {208V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,217), 125-480 V MPPT tracking, and panel fit for Tigo Energy Inc: TSI-30K-US {208V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Operating at 208 V, commercial single-phase, Tigo Energy Inc: TSI-30K-US {208V} converts DC array energy at 96.77% CEC weighted efficiency (below overall CEC median; higher than 47.8% of peers) with a 480 V max DC input and 7.14127 A max input current for NEC 690.7 string safety. Compare this 2,626 W hybrid battery-capable inverter directly with ABB: PVI-30-OUTD-S-US-A {208V} (3,000 W). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
Where Does Tigo Energy Inc: TSI-30K-US {208V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Tigo Energy Inc: TSI-30K-US {208V} at 2,626 W continuous AC output. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Tigo Energy Inc: TSI-30K-US {208V}?
Dataset percentiles comparing Tigo Energy Inc: TSI-30K-US {208V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for Tigo Energy Inc: TSI-30K-US {208V}?
Engineering highlights for Tigo Energy Inc: TSI-30K-US {208V} covering efficiency, 12 AWG Cu feeder, and panel compatibility. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
96.77% CEC Weighted Efficiency
+0.36 pts vs the 96.41% 208 V median; overall power rank #1,756 (2,626 W, below CEC median; higher than 25.0% of peers).
20 A Required Backfeed OCPD
125% x 12.6 A = 15.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).
125 V - 480 V (Max 480 V DC)
Tracking span of 355.0 V; listed since 2023-10-11 (hybrid battery-capable inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2626.0W / 208 V -> 12.6 A | Breaker >= 1.25 * 12.6 = 15.8 A -> 20 A
CEC Inverters.csv for Tigo Energy Inc: TSI-30K-US {208V}: Paco=2626.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.77%.
Result: Min 20 A breaker & 12 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Tigo Energy Inc: TSI-30K-US {208V}?
California Energy Commission Solar Equipment List parameters for Tigo Energy Inc: TSI-30K-US {208V} (hybrid battery-capable inverter) interconnection. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,626 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 125 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 7.14127 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.77% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-10-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Tigo Energy Inc: TSI-30K-US {208V} (208 V, commercial single-phase)?
Panelboard and switchgear backfeed allowances for Tigo Energy Inc: TSI-30K-US {208V} (20 A OCPD). Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 20 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 20 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 20 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 20 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 20 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Tigo Energy Inc: TSI-30K-US {208V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Tigo Energy Inc: TSI-30K-US {208V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 4 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 4 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Tigo Energy Inc: TSI-30K-US {208V}?
Four alternative CEC inverters matched to Tigo Energy Inc: TSI-30K-US {208V} (2,626 W AC), led by ABB: PVI-30-OUTD-S-US-A {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: PVI-30-OUTD-S-US-A {208V} ABB |
3,000 W | +374 W | 208.0 V | 480.0 V | 95.47% |
| ABB: PVI-30-OUTD-S-US-Z-A {208V} ABB |
3,000 W | +374 W | 208.0 V | 480.0 V | 95.47% |
| ABB: PVI-30-OUTD-S-US-Z-M-A {208V} ABB |
3,000 W | +374 W | 208.0 V | 480.0 V | 95.47% |
| ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V} ABB |
3,000 W | +374 W | 208.0 V | 480.0 V | 95.8% |
What Are the Interconnection Limits and Best-Fit Uses for Tigo Energy Inc: TSI-30K-US {208V}?
Check Tigo Energy Inc: TSI-30K-US {208V} (2,626 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Tigo Energy Inc: TSI-30K-US {208V}.
Tigo Energy Inc: TSI-30K-US {208V} Panel & Wire Spec
Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (12.6 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.77%) and MPPT window (125-480 V) directly against ABB: PVI-30-OUTD-S-US-A {208V} (3,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Tigo Energy Inc: TSI-30K-US {208V} by Tigo Energy Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Tigo Energy Inc: TSI-30K-US {208V} require?
At 2,626 W continuous AC (208 V, commercial single-phase), continuous current is 12.6 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Tigo Energy Inc: TSI-30K-US {208V} require?
At 2,626 W AC and 208 V, commercial single-phase, continuous line current is 12.6 A, requiring a 20 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Tigo Energy Inc: TSI-30K-US {208V} compare to ABB: PVI-30-OUTD-S-US-A {208V}?
Tigo Energy Inc: TSI-30K-US {208V} delivers 2,626 W AC at 96.77% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-30-OUTD-S-US-A {208V} outputs 3,000 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)