Tigo Energy Inc: TSI-100K-US {208V} outputs 8,760 W AC at 208 V, commercial single-phase (42.1 A continuous, 60 A OCPD), ranking #721 of 2,343 CEC inverters at 97.25% efficiency with a 250-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 8,760 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 97.25%
How Does Tigo Energy Inc: TSI-100K-US {208V} Compare Against Peer CEC Listings?
How Tigo Energy Inc Tigo Energy Inc: TSI-100K-US {208V} compares on 97.25% efficiency, MPPT span, and 120% busbar interconnection.
Tigo Energy Inc certifies Tigo Energy Inc: TSI-100K-US {208V} (hybrid battery-capable inverter, listed since 2023-10-11) at 8,760 W AC (3,760 W above the 5,000 W 208 V median). Its 480 V DC ceiling pairs with an MPPT window of 250-480 V (span 230.0 V). Under NEC 690.8/705.12, 125% sizing demands 6 AWG Cu conductors on a 60 A OCPD.
Where Does Tigo Energy Inc: TSI-100K-US {208V} Fall Across Listed CEC Models?
Position of Tigo Energy Inc: TSI-100K-US {208V} (8,760 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Tigo Energy Inc: TSI-100K-US {208V}?
Percentile placement of Tigo Energy Inc: TSI-100K-US {208V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Tigo Energy Inc: TSI-100K-US {208V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Tigo Energy Inc: TSI-100K-US {208V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
97.25% CEC Weighted Efficiency
+0.84 pts vs the 96.41% 208 V median; overall power rank #1,046 (8,760 W, top 44.7%; higher than 55.3% of peers).
60 A Required Backfeed OCPD
125% x 42.1 A = 52.6 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
250 V - 480 V (Max 480 V DC)
Tracking span of 230.0 V; listed since 2023-10-11 (hybrid battery-capable inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 8760.0W / 208 V -> 42.1 A | Breaker >= 1.25 * 42.1 = 52.6 A -> 60 A
CEC Inverters.csv for Tigo Energy Inc: TSI-100K-US {208V}: Paco=8760.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=97.25%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for Tigo Energy Inc: TSI-100K-US {208V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Tigo Energy Inc: TSI-100K-US {208V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 8,760 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 250 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 23.7052 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.25% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2023-10-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Tigo Energy Inc: TSI-100K-US {208V} (208 V, commercial single-phase)?
Check whether Tigo Energy Inc: TSI-100K-US {208V} (60 A breaker) fits without main breaker derate or supply-side taps.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 60 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (208V) | 80 A | 60 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 60 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 60 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 60 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With Tigo Energy Inc: TSI-100K-US {208V}?
Verified cold-weather (-10 C) series module counts matched to Tigo Energy Inc: TSI-100K-US {208V}'s 480 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Tigo Energy Inc: TSI-100K-US {208V}?
Alternative CEC inverters comparable to Tigo Energy Inc: TSI-100K-US {208V}, including Delta Electronics: E10_BDI {208V} (8,400 W) at 208 V, commercial single-phase.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E10_BDI {208V} Delta Electronics |
8,400 W | -360 W | 208.0 V | 480.0 V | 96.86% |
| Delta Electronics: E10-TL-US {208V} Delta Electronics |
8,400 W | -360 W | 208.0 V | 480.0 V | 96.86% |
| Delta Electronics: M10-4-TL-US {208V} Delta Electronics |
8,385 W | -375 W | 208.0 V | 480.0 V | 96.94% |
| Delta Electronics: M10-TL-US {208V} Delta Electronics |
8,360 W | -400 W | 208.0 V | 480.0 V | 96.83% |
What Are the Interconnection Limits and Best-Fit Uses for Tigo Energy Inc: TSI-100K-US {208V}?
Check Tigo Energy Inc: TSI-100K-US {208V} (8,760 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Tigo Energy Inc: TSI-100K-US {208V}.
Tigo Energy Inc: TSI-100K-US {208V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.25%) and MPPT window (250-480 V) directly against Delta Electronics: E10_BDI {208V} (8,400 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Tigo Energy Inc: TSI-100K-US {208V} by Tigo Energy Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does Tigo Energy Inc: TSI-100K-US {208V} require?
At 8,760 W continuous AC (208 V, commercial single-phase), continuous current is 42.1 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does Tigo Energy Inc: TSI-100K-US {208V} require?
At 8,760 W AC and 208 V, commercial single-phase, continuous line current is 42.1 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does Tigo Energy Inc: TSI-100K-US {208V} compare to Delta Electronics: E10_BDI {208V}?
Tigo Energy Inc: TSI-100K-US {208V} delivers 8,760 W AC at 97.25% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E10_BDI {208V} outputs 8,400 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)