Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

SRNE Solar CoLtd: HESP48120U200-H {208V} — CEC Inverter Specifications

Manufacturer: SRNE Solar CoLtd Registry: CEC Verified Engineering Specification

SRNE Solar CoLtd: HESP48120U200-H {208V} outputs 10,397 W AC at 208 V, commercial single-phase (50.0 A continuous, 70 A OCPD), ranking #2,199 of 2,343 CEC inverters at 95.4% efficiency with a 275-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,397 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
95.4%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SRNE Solar CoLtd: HESP48120U200-H {208V} Compare Against Peer CEC Listings?

Breaker sizing (70 A), 4 AWG Cu wire rules, and DC input limits for SRNE Solar CoLtd: HESP48120U200-H {208V}.

Classified as a hybrid battery-capable inverter (active in CEC directory), SRNE Solar CoLtd: HESP48120U200-H {208V} requires 62.5 A design capacity -> 70 A breaker using 4 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 95.4% (-1.42 pts vs overall CEC median) across 2,343 CEC models, while commercial 208 v, commercial single-phase switchgear interconnection uses 1,200a bus / 1,200a main (208v) or nec 705.11 supply-side tap.

Where Does SRNE Solar CoLtd: HESP48120U200-H {208V} Fall Across Listed CEC Models?

Output power comparison showing where SRNE Solar CoLtd: HESP48120U200-H {208V} sits among all 2,343 CEC-listed grid-support inverters. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SRNE Solar CoLtd: HESP48120U200-H {208V} (10,397 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSRNE Solar CoLtd: : 10,397 W

What Dataset Percentiles Define SRNE Solar CoLtd: HESP48120U200-H {208V}?

Relative ranking of SRNE Solar CoLtd: HESP48120U200-H {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

SRNE Solar CoLtd: HESP48120U200-H {208V} Technical ThresholdsPercentile comparison for SRNE Solar CoLtd: HESP48120U200-H {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,397 WCEC Efficiency95.4%Backfeed Breaker70 A

What Do the Dataset Ranks Show for SRNE Solar CoLtd: HESP48120U200-H {208V}?

Snapshot of SRNE Solar CoLtd: HESP48120U200-H {208V} efficiency rank (#2,199), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,199 / 2,343

95.4% CEC Weighted Efficiency

-1.01 pts vs the 96.41% 208 V median; overall power rank #826 (10,397 W, top 35.3%; higher than 64.7% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 50.0 A = 62.5 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

275 V - 450 V (Max 450 V DC)

Tracking span of 175.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10397.0W / 208 V -> 50.0 A | Breaker >= 1.25 * 50.0 = 62.5 A -> 70 A

CEC Inverters.csv for SRNE Solar CoLtd: HESP48120U200-H {208V}: Paco=10397.0 W, Vac=208 V, Vdcmax=450.0 V, Eff=95.4%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for SRNE Solar CoLtd: HESP48120U200-H {208V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SRNE Solar CoLtd: HESP48120U200-H {208V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for SRNE Solar CoLtd: HESP48120U200-H {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,397 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 450 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 275 V - 450 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 30.0636 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.4% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SRNE Solar CoLtd: HESP48120U200-H {208V} (208 V, commercial single-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for SRNE Solar CoLtd: HESP48120U200-H {208V} at 208 V, commercial single-phase.

Evaluates SRNE Solar CoLtd: HESP48120U200-H {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 70 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 70 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 70 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 70 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 70 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With SRNE Solar CoLtd: HESP48120U200-H {208V}?

Minimum and maximum series solar module strings fitting SRNE Solar CoLtd: HESP48120U200-H {208V} MPPT and 450 V limits.

Sampled CEC PV modules aligned within 275.0-450.0 V MPPT and 450.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 7 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 9 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 10 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SRNE Solar CoLtd: HESP48120U200-H {208V}?

Peer 208 V, commercial single-phase CEC inverters near 10,397 W AC output such as EG4 Electronics LLC: 18KPV-12LV {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W +102 W 208.0 V 480.0 V 96.07%
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W -340 W 208.0 V 480.0 V 96.7%
Altenergy Power System Inc: ELS-114 {208V}
Altenergy Power System Inc
10,011 W -386 W 208.0 V 60.0 V 92.83%
Chint Power Systems America: CPS ECH96KTL/US {208V}
Chint Power Systems America
9,550 W -847 W 208.0 V 480.0 V 96.73%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SRNE Solar CoLtd: HESP48120U200-H {208V}?

Check SRNE Solar CoLtd: HESP48120U200-H {208V} (10,397 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on SRNE Solar CoLtd: HESP48120U200-H {208V}.

SRNE Solar CoLtd: HESP48120U200-H {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (50.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.4%) and MPPT window (275-450 V) directly against EG4 Electronics LLC: 18KPV-12LV {208V} (10,499 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SRNE Solar CoLtd: HESP48120U200-H {208V} by SRNE Solar CoLtd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does SRNE Solar CoLtd: HESP48120U200-H {208V} require?

At 10,397 W continuous AC (208 V, commercial single-phase), continuous current is 50.0 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does SRNE Solar CoLtd: HESP48120U200-H {208V} require?

At 10,397 W AC and 208 V, commercial single-phase, continuous line current is 50.0 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does SRNE Solar CoLtd: HESP48120U200-H {208V} compare to EG4 Electronics LLC: 18KPV-12LV {208V}?

SRNE Solar CoLtd: HESP48120U200-H {208V} delivers 10,397 W AC at 95.4% CEC efficiency with a 450 V DC ceiling, while EG4 Electronics LLC: 18KPV-12LV {208V} outputs 10,499 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.