SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} outputs 962 W AC at 208 V, commercial single-phase (4.6 A continuous, 15 A OCPD), ranking #1,821 of 2,343 CEC inverters at 96.24% efficiency with a 35-50 V MPPT window and 50 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 962 W
- AC Voltage
- 208 V, commercial single-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.24%
How Does SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} Compare Against Peer CEC Listings?
Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}.
For NEC 705.12 solar interconnection, SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} outputs 4.6 A continuous AC at 208 V, commercial single-phase and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Conversion efficiency scores 96.24% (#1,821 of 2,343, -0.58 pts vs overall CEC median).
Where Does SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} Fall Across Listed CEC Models?
Output power comparison showing where SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Relative ranking of SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Snapshot of SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} efficiency rank (#1,821), OCPD breaker size, MPPT span, and busbar verdict.
96.24% CEC Weighted Efficiency
-0.17 pts vs the 96.41% 208 V median; overall power rank #1,844 (962 W, below CEC median; higher than 21.2% of peers).
15 A Required Backfeed OCPD
125% x 4.6 A = 5.8 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
35 V - 50 V (Max 50 V DC)
Tracking span of 15.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 962.0W / 208 V -> 4.6 A | Breaker >= 1.25 * 4.6 = 5.8 A -> 15 A
CEC Inverters.csv for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}: Paco=962.0 W, Vac=208 V, Vdcmax=50.0 V, Eff=96.24%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 962 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 208 V, commercial single-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 50 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 35 V - 50 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 23.7993 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.24% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} (208 V, commercial single-phase)?
NEC 705.12(B)(3)(2) backfeed compliance table for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} at 208 V, commercial single-phase.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (208V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (208V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (208V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (208V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (208V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Minimum and maximum series solar module strings fitting SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} MPPT and 50 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Peer 208 V, commercial single-phase CEC inverters near 962 W AC output such as Cherry Solution Co Ltd: CMI-1000S-SA {208V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Cherry Solution Co Ltd: CMI-1000S-SA {208V} Cherry Solution Co Ltd |
994 W | +32 W | 208.0 V | 50.0 V | 96.35% |
| Cherry Solution Co Ltd: CMI-1000S-WA {208V} Cherry Solution Co Ltd |
994 W | +32 W | 208.0 V | 50.0 V | 96.35% |
| Cherry Solution Co Ltd: CMI-800S-SA {208V} Cherry Solution Co Ltd |
800 W | -162 W | 208.0 V | 50.0 V | 95.84% |
| Cherry Solution Co Ltd: CMI-800S-WA {208V} Cherry Solution Co Ltd |
800 W | -162 W | 208.0 V | 50.0 V | 95.84% |
What Are the Interconnection Limits and Best-Fit Uses for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}?
Check SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} (962 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 50 V DC on SPITZER ENERGY COMPANY: SPZ-M1000-W {208V}.
SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (4.6 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.24%) and MPPT window (35-50 V) directly against Cherry Solution Co Ltd: CMI-1000S-SA {208V} (994 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} by SPITZER ENERGY COMPANY covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.
What breaker and wire size does SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} require?
At 962 W continuous AC (208 V, commercial single-phase), continuous current is 4.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} require?
At 962 W AC and 208 V, commercial single-phase, continuous line current is 4.6 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.
How does SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} compare to Cherry Solution Co Ltd: CMI-1000S-SA {208V}?
SPITZER ENERGY COMPANY: SPZ-M1000-W {208V} delivers 962 W AC at 96.24% CEC efficiency with a 50 V DC ceiling, while Cherry Solution Co Ltd: CMI-1000S-SA {208V} outputs 994 W at 208 V, commercial single-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)