SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} — CEC Inverter Specifications

Manufacturer: SPITZER ENERGY COMPANY Registry: CEC Verified Engineering Specification

SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} outputs 10,147 W AC at 240 V (42.3 A continuous, 60 A OCPD), ranking #1,467 of 2,343 CEC inverters at 96.56% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,147 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
96.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,467), 200-480 V MPPT tracking, and panel fit for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}.

Operating at 240 V, SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} converts DC array energy at 96.56% CEC weighted efficiency (below overall CEC median; higher than 36.1% of peers) with a 480 V max DC input and 29.1916 A max input current for NEC 690.7 string safety. Compare this 10,147 W hybrid battery-capable inverter directly with Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.

Where Does SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} at 10,147 W continuous AC output. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (10,147 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSPITZER ENERGY COM: 10,147 W

What Dataset Percentiles Define SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Dataset percentiles comparing SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} against 2,343 certified grid-support inverters nationwide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} Technical ThresholdsPercentile comparison for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,147 WCEC Efficiency96.56%Backfeed Breaker60 A

What Do the Dataset Ranks Show for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Engineering highlights for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #1,467 / 2,343

96.56% CEC Weighted Efficiency

-0.12 pts vs the 96.68% 240 V median; overall power rank #852 (10,147 W, top 36.4%; higher than 63.6% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 42.3 A = 52.9 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-01-13 (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10147.0W / 240 V -> 42.3 A | Breaker >= 1.25 * 42.3 = 52.9 A -> 60 A

CEC Inverters.csv for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}: Paco=10147.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.56%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

California Energy Commission Solar Equipment List parameters for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,147 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.1916 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.56% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-01-13 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Panelboard and switchgear backfeed allowances for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (60 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Four alternative CEC inverters matched to SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (10,147 W AC), led by Amensolar Ess Co Ltd: N3H-X100-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Amensolar Ess Co Ltd: N3H-X100-US {240V}
Amensolar Ess Co Ltd
10,177 W +30 W 240.0 V 430.0 V 97.15%
Amensolar Ess Co Ltd: N3H-X10US {240V}
Amensolar Ess Co Ltd
10,177 W +30 W 240.0 V 430.0 V 97.15%
Base Power Inc: MIN 10000TL-XH-US {240V}
Base Power Inc
10,082 W -65 W 240.0 V 480.0 V 97.61%
Delta Electronics: E10_BDI {240V}
Delta Electronics
9,674 W -473 W 240.0 V 480.0 V 97.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}?

Check SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} (10,147 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V}.

SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (42.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.56%) and MPPT window (200-480 V) directly against Amensolar Ess Co Ltd: N3H-X100-US {240V} (10,177 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} by SPITZER ENERGY COMPANY covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} require?

At 10,147 W continuous AC (240 V), continuous current is 42.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} compare to Amensolar Ess Co Ltd: N3H-X100-US {240V}?

SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V} delivers 10,147 W AC at 96.56% CEC efficiency with a 480 V DC ceiling, while Amensolar Ess Co Ltd: N3H-X100-US {240V} outputs 10,177 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.