Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} — CEC Inverter Specifications

Manufacturer: Shenzhen Poweroak Newener Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} outputs 5,777 W AC at 240 V (24.1 A continuous, 35 A OCPD), ranking #2,234 of 2,343 CEC inverters at 95.22% efficiency with a 63-87 V MPPT window and 87 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,777 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
95.22%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}.

Ranking #1,432 of 2,343 CEC inverters (below CEC median; higher than 38.9% of peers), Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} is a grid-tied PV inverter delivering 5,777 W continuous AC at 240 V (24.1 A continuous). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 95.22% (-1.46 pts vs the 96.68% 240 V median) against peers like Delta Electronics: E6-TL-US {240V} (5,760 W).

Where Does Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} Fall Across Listed CEC Models?

Marks Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} (5,777 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} (5,777 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Poweroak : 5,777 W

What Dataset Percentiles Define Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Benchmarks Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} continuous AC output, 95.22% CEC weighted efficiency, and 35 A OCPD breaker demand.

Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} Technical ThresholdsPercentile comparison for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,777 WCEC Efficiency95.22%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} by Shenzhen Poweroak Newener Co Ltd.

Eff #2,234 / 2,343

95.22% CEC Weighted Efficiency

-1.46 pts vs the 96.68% 240 V median; overall power rank #1,432 (5,777 W, below CEC median; higher than 38.9% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

63 V - 87 V (Max 87 V DC)

Tracking span of 24.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5777.0W / 240 V -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A

CEC Inverters.csv for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}: Paco=5777.0 W, Vac=240 V, Vdcmax=87.0 V, Eff=95.22%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,777 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 87 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 63 V - 87 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 79.8311 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.22% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Evaluates Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} (35 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Sample PV string lengths aligned within 63-87 V MPPT and 87 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 63.0-87.0 V MPPT and 87.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 1 panel (micro/module) 0.59 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 2 panels (fixed) 0.88 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Competing CEC grid-support inverters near 5,777 W AC and 240 V, led by Delta Electronics: E6-TL-US {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E6-TL-US {240V}
Delta Electronics
5,760 W -17 W 240.0 V 480.0 V 97.35%
Delta Electronics: M6-TL-US {240V}
Delta Electronics
5,760 W -17 W 240.0 V 480.0 V 97.37%
Delta Electronics: E6_BDI {240V}
Delta Electronics
5,823 W +46 W 240.0 V 480.0 V 97.63%
Base Power Inc: MIN 6000TL-XH-US {240V}
Base Power Inc
5,918 W +141 W 240.0 V 480.0 V 97.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}?

Check Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} (5,777 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 87 V DC on Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V}.

Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.22%) and MPPT window (63-87 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} by Shenzhen Poweroak Newener Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} require?

At 5,777 W continuous AC (240 V), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} compare to Delta Electronics: E6-TL-US {240V}?

Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V} delivers 5,777 W AC at 95.22% CEC efficiency with a 87 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.