Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} outputs 4,004 W AC at 208 V, commercial single-phase (19.2 A continuous, 25 A OCPD), ranking #2,010 of 2,343 CEC inverters at 95.96% efficiency with a 150-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,004 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
25 A (10 AWG Cu)
CEC Efficiency
95.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}.

Rated at 4,004 W AC (19.2 A continuous), Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} ranks #2,010 of 2,343 CEC units at 95.96% efficiency (-0.45 pts vs the 96.41% 208 V median). Minimum 75 C copper conductor sizing for its 25 A circuit is 10 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.

Where Does Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} Fall Across Listed CEC Models?

Marks Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (4,004 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (4,004 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 4,004 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Benchmarks Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} continuous AC output, 95.96% CEC weighted efficiency, and 25 A OCPD breaker demand.

Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,004 WCEC Efficiency95.96%Backfeed Breaker25 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} by Shenzhen Growatt New Energy Co Ltd.

Eff #2,010 / 2,343

95.96% CEC Weighted Efficiency

-0.45 pts vs the 96.41% 208 V median; overall power rank #1,623 (4,004 W, below CEC median; higher than 30.7% of peers).

NEC 705.12 Check

25 A Required Backfeed OCPD

125% x 19.2 A = 24.0 A -> 25 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

150 V - 480 V (Max 480 V DC)

Tracking span of 330.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4004.0W / 208 V -> 19.2 A | Breaker >= 1.25 * 19.2 = 24.0 A -> 25 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}: Paco=4004.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=95.96%.

Result: Min 25 A breaker & 10 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,004 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 150 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 10.9806 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.96% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (208 V, commercial single-phase)?

Evaluates Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (25 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (25 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 25 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 25 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 25 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 25 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 25 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Sample PV string lengths aligned within 150-480 V MPPT and 480 V DC max at -10 C. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 150.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 4 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 5 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 5 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 6 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Competing CEC grid-support inverters near 4,004 W AC and 208 V, commercial single-phase, led by Delta Electronics: M5-TL-US {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: M5-TL-US {208V}
Delta Electronics
4,160 W +156 W 208.0 V 480.0 V 97.35%
ABB: PVI-42-OUTD-S-US-A {208V}
ABB
4,200 W +196 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-A {208V}
ABB
4,200 W +196 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-M-A {208V}
ABB
4,200 W +196 W 208.0 V 480.0 V 95.6%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}?

Check Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} (4,004 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V}.

Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (19.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.96%) and MPPT window (150-480 V) directly against Delta Electronics: M5-TL-US {208V} (4,160 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} require?

At 4,004 W continuous AC (208 V, commercial single-phase), continuous current is 19.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} require?

At 4,004 W AC and 208 V, commercial single-phase, continuous line current is 19.2 A, requiring a 25 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} compare to Delta Electronics: M5-TL-US {208V}?

Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V} delivers 4,004 W AC at 95.96% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: M5-TL-US {208V} outputs 4,160 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.