Delta Electronics: M5-TL-US {208V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: M5-TL-US {208V} outputs 4,160 W AC at 208 V, commercial single-phase (20.0 A continuous, 25 A OCPD), ranking #654 of 2,343 CEC inverters at 97.35% efficiency with a 220-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,160 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
25 A (10 AWG Cu)
CEC Efficiency
97.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: M5-TL-US {208V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 208 V, commercial single-phase grid-support overview for Delta Electronics: M5-TL-US {208V}.

Ranking #1,620 of 2,343 CEC inverters (below CEC median; higher than 30.9% of peers), Delta Electronics: M5-TL-US {208V} is a grid-tied PV inverter delivering 4,160 W continuous AC at 208 V, commercial single-phase (20.0 A continuous). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.35% (+0.94 pts vs the 96.41% 208 V median) against peers like ABB: PVI-42-OUTD-S-US-A {208V} (4,200 W).

Where Does Delta Electronics: M5-TL-US {208V} Fall Across Listed CEC Models?

Marks Delta Electronics: M5-TL-US {208V} (4,160 W AC) across the California Energy Commission inverter AC capacity distribution. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: M5-TL-US {208V} (4,160 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 4,160 W

What Dataset Percentiles Define Delta Electronics: M5-TL-US {208V}?

Benchmarks Delta Electronics: M5-TL-US {208V} continuous AC output, 97.35% CEC weighted efficiency, and 25 A OCPD breaker demand.

Delta Electronics: M5-TL-US {208V} Technical ThresholdsPercentile comparison for Delta Electronics: M5-TL-US {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,160 WCEC Efficiency97.35%Backfeed Breaker25 A

What Do the Dataset Ranks Show for Delta Electronics: M5-TL-US {208V}?

Four key NEC 705.12 and California Energy Commission metrics defining Delta Electronics: M5-TL-US {208V} by Delta Electronics. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #654 / 2,343

97.35% CEC Weighted Efficiency

+0.94 pts vs the 96.41% 208 V median; overall power rank #1,620 (4,160 W, below CEC median; higher than 30.9% of peers).

NEC 705.12 Check

25 A Required Backfeed OCPD

125% x 20.0 A = 25.0 A -> 25 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

220 V - 480 V (Max 480 V DC)

Tracking span of 260.0 V; listed since 2023-02-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4160.0W / 208 V -> 20.0 A | Breaker >= 1.25 * 20.0 = 25.0 A -> 25 A

CEC Inverters.csv for Delta Electronics: M5-TL-US {208V}: Paco=4160.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=97.35%.

Result: Min 25 A breaker & 10 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Delta Electronics: M5-TL-US {208V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Delta Electronics: M5-TL-US {208V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: M5-TL-US {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,160 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 220 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.2456 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.35% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-02-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Delta Electronics: M5-TL-US {208V} (208 V, commercial single-phase)?

Evaluates Delta Electronics: M5-TL-US {208V} (25 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Delta Electronics: M5-TL-US {208V} (25 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 25 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 25 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 25 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 25 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 25 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Delta Electronics: M5-TL-US {208V}?

Sample PV string lengths aligned within 220-480 V MPPT and 480 V DC max at -10 C. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sampled CEC PV modules aligned within 220.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 7 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: M5-TL-US {208V}?

Competing CEC grid-support inverters near 4,160 W AC and 208 V, commercial single-phase, led by ABB: PVI-42-OUTD-S-US-A {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-42-OUTD-S-US-A {208V}
ABB
4,200 W +40 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-A {208V}
ABB
4,200 W +40 W 208.0 V 480.0 V 95.6%
ABB: PVI-42-OUTD-S-US-Z-M-A {208V}
ABB
4,200 W +40 W 208.0 V 480.0 V 95.6%
ABB: UNO-DM-46-TL-PLUS-US-SB-RA {208V}
ABB
4,200 W +40 W 208.0 V 480.0 V 95.61%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: M5-TL-US {208V}?

Check Delta Electronics: M5-TL-US {208V} (4,160 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Delta Electronics: M5-TL-US {208V}.

Delta Electronics: M5-TL-US {208V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (20.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.35%) and MPPT window (220-480 V) directly against ABB: PVI-42-OUTD-S-US-A {208V} (4,200 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: M5-TL-US {208V} by Delta Electronics covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Delta Electronics: M5-TL-US {208V} require?

At 4,160 W continuous AC (208 V, commercial single-phase), continuous current is 20.0 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Delta Electronics: M5-TL-US {208V} require?

At 4,160 W AC and 208 V, commercial single-phase, continuous line current is 20.0 A, requiring a 25 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Delta Electronics: M5-TL-US {208V} compare to ABB: PVI-42-OUTD-S-US-A {208V}?

Delta Electronics: M5-TL-US {208V} delivers 4,160 W AC at 97.35% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-42-OUTD-S-US-A {208V} outputs 4,200 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.