Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} outputs 3,608 W AC at 240 V (15.0 A continuous, 20 A OCPD), ranking #2,177 of 2,343 CEC inverters at 95.47% efficiency with a 150-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,608 W
- AC Voltage
- 240 V
- Min PV Breaker
- 20 A (12 AWG Cu)
- CEC Efficiency
- 95.47%
How Does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} Compare Against Peer CEC Listings?
How Shenzhen Growatt New Energy Co Ltd Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} compares on 95.47% efficiency, MPPT span, and 120% busbar interconnection.
With a 150-480 V MPPT tracking band and 480 V DC ceiling, Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} handles 3,608 W continuous AC (2,168 W below the 5,776 W 240 V median). Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing Shenzhen Growatt New Energy Co Ltd against ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.
Where Does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} Fall Across Listed CEC Models?
Position of Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} (3,608 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Percentile placement of Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}.
95.47% CEC Weighted Efficiency
-1.21 pts vs the 96.68% 240 V median; overall power rank #1,682 (3,608 W, below CEC median; higher than 28.2% of peers).
20 A Required Backfeed OCPD
125% x 15.0 A = 18.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).
150 V - 480 V (Max 480 V DC)
Tracking span of 330.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3608.0W / 240 V -> 15.0 A | Breaker >= 1.25 * 15.0 = 18.8 A -> 20 A
CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}: Paco=3608.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=95.47%.
Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,608 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 150 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 9.94556 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.47% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Check whether Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} (20 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 20 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 20 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 20 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 20 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 20 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Verified cold-weather (-10 C) series module counts matched to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}'s 480 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 5 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 5 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 6 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Alternative CEC inverters comparable to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}, including ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: PVI-36-OUTD-S-US-A {240V} ABB |
3,600 W | -8 W | 240.0 V | 480.0 V | 96.26% |
| ABB: PVI-36-OUTD-S-US-Z-A {240V} ABB |
3,600 W | -8 W | 240.0 V | 480.0 V | 96.26% |
| ABB: PVI-36-OUTD-S-US-Z-M-A {240V} ABB |
3,600 W | -8 W | 240.0 V | 480.0 V | 96.26% |
| Altenergy Power System Inc: ELS-3K {240V} Altenergy Power System Inc |
3,685 W | +77 W | 240.0 V | 60.0 V | 94.4% |
What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}?
Check Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} (3,608 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V}.
Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.47%) and MPPT window (150-480 V) directly against ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} require?
At 3,608 W continuous AC (240 V), continuous current is 15.0 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.
Does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).
How does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} compare to ABB: PVI-36-OUTD-S-US-A {240V}?
Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V} delivers 3,608 W AC at 95.47% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-36-OUTD-S-US-A {240V} outputs 3,600 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)