Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} — CEC Inverter Specifications

Manufacturer: Shenzhen Growatt New Energy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} outputs 3,581 W AC at 208 V, commercial single-phase (17.2 A continuous, 25 A OCPD), ranking #2,124 of 2,343 CEC inverters at 95.68% efficiency with a 150-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,581 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
25 A (10 AWG Cu)
CEC Efficiency
95.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} Compare Against Peer CEC Listings?

How Shenzhen Growatt New Energy Co Ltd Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} compares on 95.68% efficiency, MPPT span, and 120% busbar interconnection.

Shenzhen Growatt New Energy Co Ltd certifies Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (hybrid battery-capable inverter, active in CEC directory) at 3,581 W AC (1,419 W below the 5,000 W 208 V median). Its 480 V DC ceiling pairs with an MPPT window of 150-480 V (span 330.0 V). Under NEC 690.8/705.12, 125% sizing demands 10 AWG Cu conductors on a 25 A OCPD.

Where Does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} Fall Across Listed CEC Models?

Position of Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (3,581 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (3,581 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 3,581 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Percentile placement of Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} across AC power class, conversion efficiency, and backfeed breaker size.

Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,581 WCEC Efficiency95.68%Backfeed Breaker25 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}.

Eff #2,124 / 2,343

95.68% CEC Weighted Efficiency

-0.73 pts vs the 96.41% 208 V median; overall power rank #1,698 (3,581 W, below CEC median; higher than 27.5% of peers).

NEC 705.12 Check

25 A Required Backfeed OCPD

125% x 17.2 A = 21.5 A -> 25 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

150 V - 480 V (Max 480 V DC)

Tracking span of 330.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3581.0W / 208 V -> 17.2 A | Breaker >= 1.25 * 17.2 = 21.5 A -> 25 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}: Paco=3581.0 W, Vac=208 V, Vdcmax=480.0 V, Eff=95.68%.

Result: Min 25 A breaker & 10 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,581 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 150 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 9.84892 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 95.68% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (208 V, commercial single-phase)?

Check whether Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (25 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (25 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 25 A PASS (120% Commercial Busbar)
400A Bus / 400A Main (208V) 80 A 25 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 25 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 25 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 25 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Verified cold-weather (-10 C) series module counts matched to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 150.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 4 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 5 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 5 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 6 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Alternative CEC inverters comparable to Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}, including ABB: PVI-36-OUTD-S-US-A {208V} (3,600 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVI-36-OUTD-S-US-A {208V}
ABB
3,600 W +19 W 208.0 V 480.0 V 95.81%
ABB: PVI-36-OUTD-S-US-Z-A {208V}
ABB
3,600 W +19 W 208.0 V 480.0 V 95.81%
ABB: PVI-36-OUTD-S-US-Z-M-A {208V}
ABB
3,600 W +19 W 208.0 V 480.0 V 95.81%
Delta Electronics: E4-TL-US(AC) {208V}
Delta Electronics
3,364 W -217 W 208.0 V 480.0 V 98.11%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}?

Check Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} (3,581 W AC, 25 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V}.

Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 25 A OCPD breaker (17.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (95.68%) and MPPT window (150-480 V) directly against ABB: PVI-36-OUTD-S-US-A {208V} (3,600 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} require?

At 3,581 W continuous AC (208 V, commercial single-phase), continuous current is 17.2 A; 125% NEC 690.8/705.12 sizing requires a 25 A breaker and 10 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} require?

At 3,581 W AC and 208 V, commercial single-phase, continuous line current is 17.2 A, requiring a 25 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} compare to ABB: PVI-36-OUTD-S-US-A {208V}?

Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V} delivers 3,581 W AC at 95.68% CEC efficiency with a 480 V DC ceiling, while ABB: PVI-36-OUTD-S-US-A {208V} outputs 3,600 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.