Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} — CEC Inverter Specifications

Manufacturer: Shenzhen Growatt New Energy Co Ltd Registry: CEC Verified Engineering Specification

Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} outputs 9,061 W AC at 240 V (37.8 A continuous, 50 A OCPD), ranking #711 of 2,343 CEC inverters at 97.26% efficiency with a 330-550 V MPPT window and 550 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,061 W
AC Voltage
240 V
Min PV Breaker
50 A (8 AWG Cu)
CEC Efficiency
97.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}.

Rated at 9,061 W AC (37.8 A continuous), Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} ranks #711 of 2,343 CEC units at 97.26% efficiency (+0.58 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 50 A circuit is 8 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 550 V DC at record local winter lows.

Where Does Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} Fall Across Listed CEC Models?

Marks Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} (9,061 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} (9,061 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACShenzhen Growatt N: 9,061 W

What Dataset Percentiles Define Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Benchmarks Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} continuous AC output, 97.26% CEC weighted efficiency, and 50 A OCPD breaker demand.

Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} Technical ThresholdsPercentile comparison for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,061 WCEC Efficiency97.26%Backfeed Breaker50 A

What Do the Dataset Ranks Show for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} by Shenzhen Growatt New Energy Co Ltd.

Eff #711 / 2,343

97.26% CEC Weighted Efficiency

+0.58 pts vs the 96.68% 240 V median; overall power rank #1,013 (9,061 W, top 43.2%; higher than 56.8% of peers).

NEC 705.12 Check

50 A Required Backfeed OCPD

125% x 37.8 A = 47.2 A -> 50 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

330 V - 550 V (Max 550 V DC)

Tracking span of 220.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9061.0W / 240 V -> 37.8 A | Breaker >= 1.25 * 37.8 = 47.2 A -> 50 A

CEC Inverters.csv for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}: Paco=9061.0 W, Vac=240 V, Vdcmax=550.0 V, Eff=97.26%.

Result: Min 50 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,061 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 550 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 330 V - 550 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 19.4096 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.26% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Evaluates Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} (50 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} (50 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 50 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 50 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 50 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 50 A PASS (120% Rule)
225A Bus / 200A Main 70 A 50 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Sample PV string lengths aligned within 330-550 V MPPT and 550 V DC max at -10 C. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sampled CEC PV modules aligned within 330.0-550.0 V MPPT and 550.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 8 to 9 panels 5.31 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 10 to 13 panels 5.72 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 10 to 12 panels 5.1 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 12 to 13 panels 2.6 kW

Which Competing Grid-Support Inverters Compare to Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Competing CEC grid-support inverters near 9,061 W AC and 240 V, led by Base Power Inc: MIN 9000TL-XH-US {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Base Power Inc: MIN 9000TL-XH-US {240V}
Base Power Inc
9,063 W +2 W 240.0 V 480.0 V 97.69%
ABB: UNO-86-TL-OUTD-S-US-A {240V}
ABB
8,600 W -461 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-A {240V}
ABB
8,600 W -461 W 240.0 V 480.0 V 97.03%
ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V}
ABB
8,600 W -461 W 240.0 V 480.0 V 97.03%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}?

Check Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} (9,061 W AC, 50 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 50 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 550 V DC on Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V}.

Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 50 A OCPD breaker (37.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.26%) and MPPT window (330-550 V) directly against Base Power Inc: MIN 9000TL-XH-US {240V} (9,063 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} by Shenzhen Growatt New Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} require?

At 9,061 W continuous AC (240 V), continuous current is 37.8 A; 125% NEC 690.8/705.12 sizing requires a 50 A breaker and 8 AWG Cu (75 C) wire.

Does Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 50 A at 240 V means Needs Derate / Tap 705.11.

How does Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} compare to Base Power Inc: MIN 9000TL-XH-US {240V}?

Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V} delivers 9,061 W AC at 97.26% CEC efficiency with a 550 V DC ceiling, while Base Power Inc: MIN 9000TL-XH-US {240V} outputs 9,063 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.