Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} outputs 11,370 W AC at 240 V (47.4 A continuous, 60 A OCPD), ranking #906 of 2,343 CEC inverters at 97.08% efficiency with a 300-440 V MPPT window and 440 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 11,370 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 97.08%
How Does Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#906), 300-440 V MPPT tracking, and panel fit for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}.
Operating at 240 V, Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} converts DC array energy at 97.08% CEC weighted efficiency (top 39.1%; higher than 60.9% of peers) with a 440 V max DC input and 31.6545 A max input current for NEC 690.7 string safety. Compare this 11,370 W hybrid battery-capable inverter directly with Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
Where Does Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} at 11,370 W continuous AC output.
What Dataset Percentiles Define Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Dataset percentiles comparing Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} against 2,343 certified grid-support inverters nationwide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Engineering highlights for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.
97.08% CEC Weighted Efficiency
+0.40 pts vs the 96.68% 240 V median; overall power rank #793 (11,370 W, top 33.9%; higher than 66.1% of peers).
60 A Required Backfeed OCPD
125% x 47.4 A = 59.2 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
300 V - 440 V (Max 440 V DC)
Tracking span of 140.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 11370.5W / 240 V -> 47.4 A | Breaker >= 1.25 * 47.4 = 59.2 A -> 60 A
CEC Inverters.csv for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}: Paco=11370.5 W, Vac=240 V, Vdcmax=440.0 V, Eff=97.08%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
California Energy Commission Solar Equipment List parameters for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 11,370 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 440 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 300 V - 440 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 31.6545 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.08% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Panelboard and switchgear backfeed allowances for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} (60 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 panels (fixed) | 4.13 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 9 panels (fixed) | 3.83 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 8 panels (fixed) | 4.12 kW |
Which Competing Grid-Support Inverters Compare to Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Four alternative CEC inverters matched to Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} (11,370 W AC), led by Chint Power Systems America: CPS ECH114KTL/US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH114KTL/US {240V} Chint Power Systems America |
11,360 W | -10 W | 240.0 V | 480.0 V | 96.53% |
| Altenergy Power System Inc: ELS-114 {240V} Altenergy Power System Inc |
11,415 W | +44 W | 240.0 V | 60.0 V | 93.08% |
| Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} Dyness Digital Energy Technology Co LTD |
11,498 W | +128 W | 240.0 V | 500.0 V | 96.41% |
| Dyness Digital Energy Technology Co LTD: TX114K-AM {240V} Dyness Digital Energy Technology Co LTD |
11,519 W | +148 W | 240.0 V | 490.0 V | 96.21% |
What Are the Interconnection Limits and Best-Fit Uses for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}?
Check Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} (11,370 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 440 V DC on Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V}.
Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.4 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.08%) and MPPT window (300-440 V) directly against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} by Shanghai Chelion RenewableTechnology Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} require?
At 11,370 W continuous AC (240 V), continuous current is 47.4 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?
Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V} delivers 11,370 W AC at 97.08% CEC efficiency with a 440 V DC ceiling, while Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)