Qcells North America: QMICRO380C-G2 {240V} outputs 379 W AC at 240 V (1.6 A continuous, 15 A OCPD), ranking #990 of 2,343 CEC inverters at 97.02% efficiency with a 30-40 V MPPT window and 40 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 379 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 97.02%
How Does Qcells North America: QMICRO380C-G2 {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Qcells North America: QMICRO380C-G2 {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Ranking #2,019 of 2,343 CEC inverters (below CEC median; higher than 13.8% of peers), Qcells North America: QMICRO380C-G2 {240V} is a grid-tied PV inverter delivering 379 W continuous AC at 240 V (1.6 A continuous). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Weighted CEC efficiency reaches 97.02% (+0.34 pts vs the 96.68% 240 V median) against peers like Aptos Solar Technology LLC: MAC-400 {240V} (382 W).
Where Does Qcells North America: QMICRO380C-G2 {240V} Fall Across Listed CEC Models?
Marks Qcells North America: QMICRO380C-G2 {240V} (379 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Qcells North America: QMICRO380C-G2 {240V}?
Benchmarks Qcells North America: QMICRO380C-G2 {240V} continuous AC output, 97.02% CEC weighted efficiency, and 15 A OCPD breaker demand.
What Do the Dataset Ranks Show for Qcells North America: QMICRO380C-G2 {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Qcells North America: QMICRO380C-G2 {240V} by Qcells North America.
97.02% CEC Weighted Efficiency
+0.34 pts vs the 96.68% 240 V median; overall power rank #2,019 (379 W, below CEC median; higher than 13.8% of peers).
15 A Required Backfeed OCPD
125% x 1.6 A = 2.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
30 V - 40 V (Max 40 V DC)
Tracking span of 10.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 378.9W / 240 V -> 1.6 A | Breaker >= 1.25 * 1.6 = 2.0 A -> 15 A
CEC Inverters.csv for Qcells North America: QMICRO380C-G2 {240V}: Paco=378.9 W, Vac=240 V, Vdcmax=40.0 V, Eff=97.02%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Qcells North America: QMICRO380C-G2 {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Qcells North America: QMICRO380C-G2 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 379 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 40 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 30 V - 40 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 12.0166 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.02% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Qcells North America: QMICRO380C-G2 {240V}?
Evaluates Qcells North America: QMICRO380C-G2 {240V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which Competing Grid-Support Inverters Compare to Qcells North America: QMICRO380C-G2 {240V}?
Competing CEC grid-support inverters near 379 W AC and 240 V, led by Aptos Solar Technology LLC: MAC-400 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC: MAC-400 {240V} Aptos Solar Technology LLC |
382 W | +4 W | 240.0 V | 48.0 V | 96.52% |
| Aptos Solar Technology LLC: MAC-400R {240V} Aptos Solar Technology LLC |
382 W | +4 W | 240.0 V | 48.0 V | 96.52% |
| Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Chilicon Power LLC |
289 W | -90 W | 240.0 V | 32.0 V | 95.41% |
| Altenergy Power System Inc: YC600 {240V} Altenergy Power System Inc |
550 W | +171 W | 240.0 V | 45.0 V | 96.51% |
What Are the Interconnection Limits and Best-Fit Uses for Qcells North America: QMICRO380C-G2 {240V}?
Check Qcells North America: QMICRO380C-G2 {240V} (379 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 40 V DC on Qcells North America: QMICRO380C-G2 {240V}.
Qcells North America: QMICRO380C-G2 {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.6 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.02%) and MPPT window (30-40 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Qcells North America: QMICRO380C-G2 {240V} by Qcells North America covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Qcells North America: QMICRO380C-G2 {240V} require?
At 379 W continuous AC (240 V), continuous current is 1.6 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Qcells North America: QMICRO380C-G2 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Qcells North America: QMICRO380C-G2 {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?
Qcells North America: QMICRO380C-G2 {240V} delivers 379 W AC at 97.02% CEC efficiency with a 40 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)