Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Power Electronics: FS1100CU15 {600V} — CEC Inverter Specifications

Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS1100CU15 {600V} outputs 1,209,250 W AC at 600 V, 3-phase (1163.6 A continuous, 1,500 A OCPD), ranking #495 of 2,343 CEC inverters at 97.64% efficiency with a 849-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
1,209,250 W
AC Voltage
600 V, 3-phase
Min PV Breaker
1,500 A (parallel Cu feeders)
CEC Efficiency
97.64%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS1100CU15 {600V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 600 V, 3-phase grid-support overview for Power Electronics: FS1100CU15 {600V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rated at 1,209,250 W AC (1163.6 A continuous), Power Electronics: FS1100CU15 {600V} ranks #495 of 2,343 CEC units at 97.64% efficiency (-0.64 pts vs the 98.28% 600 V median). Minimum 75 C copper conductor sizing for its 1,500 A circuit is parallel Cu feeders per NEC Table 310.16. Cold-weather string Voc must remain under 1,200 V DC at record local winter lows.

Where Does Power Electronics: FS1100CU15 {600V} Fall Across Listed CEC Models?

Marks Power Electronics: FS1100CU15 {600V} (1,209,250 W AC) across the California Energy Commission inverter AC capacity distribution. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS1100CU15 {600V} (1,209,250 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 1,209,250 W

What Dataset Percentiles Define Power Electronics: FS1100CU15 {600V}?

Benchmarks Power Electronics: FS1100CU15 {600V} continuous AC output, 97.64% CEC weighted efficiency, and 1,500 A OCPD breaker demand.

Power Electronics: FS1100CU15 {600V} Technical ThresholdsPercentile comparison for Power Electronics: FS1100CU15 {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output1,209,250 WCEC Efficiency97.64%Backfeed Breaker1,500 A

What Do the Dataset Ranks Show for Power Electronics: FS1100CU15 {600V}?

Four key NEC 705.12 and California Energy Commission metrics defining Power Electronics: FS1100CU15 {600V} by Power Electronics. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #495 / 2,343

97.64% CEC Weighted Efficiency

-0.64 pts vs the 98.28% 600 V median; overall power rank #148 (1,209,250 W, top 6.3%; higher than 93.7% of peers).

NEC 705.12 Check

1,500 A Required Backfeed OCPD

125% x 1163.6 A = 1454.5 A -> 1,500 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

849 V - 1,200 V (Max 1,200 V DC)

Tracking span of 351.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 1209250.0W / 600 V 3-phase -> 1163.6 A | Breaker >= 1.25 * 1163.6 = 1454.5 A -> 1,500 A

CEC Inverters.csv for Power Electronics: FS1100CU15 {600V}: Paco=1209250.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=97.64%.

Result: Min 1,500 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Power Electronics: FS1100CU15 {600V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Power Electronics: FS1100CU15 {600V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS1100CU15 {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 1,209,250 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 849 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 1317.56 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.64% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Power Electronics: FS1100CU15 {600V} (600 V, 3-phase)?

Evaluates Power Electronics: FS1100CU15 {600V} (1,500 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Power Electronics: FS1100CU15 {600V} (1500 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 1,500 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 1,500 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 1,500 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 1,500 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 1,500 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Power Electronics: FS1100CU15 {600V}?

Sample PV string lengths aligned within 849-1,200 V MPPT and 1,200 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 849.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 26 panels 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 21 to 22 panels 11.33 kW

Which Competing Grid-Support Inverters Compare to Power Electronics: FS1100CU15 {600V}?

Competing CEC grid-support inverters near 1,209,250 W AC and 600 V, 3-phase, led by EPC Power Corp: 50-100181 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-100181 {600V}
EPC Power Corp
1,304,151 W +94901 W 600.0 V 1500.0 V 97.93%
Sungrow Power Supply Co Ltd: SG3150UD-MV-US {600V}
Sungrow Power Supply Co Ltd
1,053,000 W -156250 W 600.0 V 1438.0 V 97.01%
Yaskawa Solectria Solar: XGI 1500-1MW-600 {600V}
Yaskawa Solectria Solar
1,000,000 W -209250 W 600.0 V 1250.0 V 98.47%
DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {600V}
DYNAPOWER COMPANY LLC
999,576 W -209674 W 600.0 V 1500.0 V 98.44%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS1100CU15 {600V}?

Check Power Electronics: FS1100CU15 {600V} (1,209,250 W AC, 1,500 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS1100CU15 {600V}.

Power Electronics: FS1100CU15 {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 1,500 A OCPD breaker (1163.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.64%) and MPPT window (849-1,200 V) directly against EPC Power Corp: 50-100181 {600V} (1,304,151 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS1100CU15 {600V} by Power Electronics covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS1100CU15 {600V} require?

At 1,209,250 W continuous AC (600 V, 3-phase), continuous current is 1163.6 A; 125% NEC 690.8/705.12 sizing requires a 1,500 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS1100CU15 {600V} require?

At 1,209,250 W AC and 600 V, 3-phase, continuous line current is 1163.6 A, requiring a 1,500 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does Power Electronics: FS1100CU15 {600V} compare to EPC Power Corp: 50-100181 {600V}?

Power Electronics: FS1100CU15 {600V} delivers 1,209,250 W AC at 97.64% CEC efficiency with a 1,200 V DC ceiling, while EPC Power Corp: 50-100181 {600V} outputs 1,304,151 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.