KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} outputs 109,765 W AC at 480 V, 3-phase (132.0 A continuous, 175 A OCPD), ranking #101 of 2,343 CEC inverters at 98.44% efficiency with a 705-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
109,765 W
AC Voltage
480 V, 3-phase
Min PV Breaker
175 A (2/0 AWG Cu)
CEC Efficiency
98.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} Compare Against Peer CEC Listings?

CEC efficiency rank (#101), 705-1,300 V MPPT tracking, and panel fit for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}.

KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} from KACO new energy GmbH outputs 132.0 A continuous AC at 480 V, 3-phase (109,765 W AC, rank #326). Paired with 2/0 AWG Cu conductors and a 175 A OCPD, its 98.44% CEC efficiency compares closely with Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V} (100,000 W). Keep NEC 690.7 winter string Voc below 1,300 V DC.

Where Does KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} at 109,765 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (109,765 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACKACO new energy Gm: 109,765 W

What Dataset Percentiles Define KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

Dataset percentiles comparing KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} against 2,343 certified grid-support inverters nationwide.

KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} Technical ThresholdsPercentile comparison for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output109,765 WCEC Efficiency98.44%Backfeed Breaker175 A

What Do the Dataset Ranks Show for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

Engineering highlights for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} covering efficiency, 2/0 AWG Cu feeder, and panel compatibility.

Eff #101 / 2,343

98.44% CEC Weighted Efficiency

+0.42 pts vs the 98.02% 480 V median; overall power rank #326 (109,765 W, top 14.0%; higher than 86.0% of peers).

NEC 705.12 Check

175 A Required Backfeed OCPD

125% x 132.0 A = 165.0 A -> 175 A standard OCPD using 2/0 AWG Cu (75 C).

MPPT Window

705 V - 1,300 V (Max 1,300 V DC)

Tracking span of 595.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 109765.0W / 480 V 3-phase -> 132.0 A | Breaker >= 1.25 * 132.0 = 165.0 A -> 175 A

CEC Inverters.csv for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}: Paco=109765.0 W, Vac=480 V, Vdcmax=1300.0 V, Eff=98.44%.

Result: Min 175 A breaker & 2/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

California Energy Commission Solar Equipment List parameters for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 109,765 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 705 V - 1,300 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 130.573 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.44% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (480 V, 3-phase)?

Panelboard and switchgear backfeed allowances for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (175 A OCPD).

Evaluates KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (175 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (480V) 120 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (480V) 160 A 175 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (480V) 240 A 175 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}.

Sampled CEC PV modules aligned within 705.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 17 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 22 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 21 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 25 to 32 panels 6.4 kW

Which Competing Grid-Support Inverters Compare to KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

Four alternative CEC inverters matched to KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (109,765 W AC), led by Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V}
Chint Power Systems America
100,000 W -9765 W 480.0 V 1300.0 V 97.79%
Chint Power Systems America: SCA100K-T-US-480 {480V}
Chint Power Systems America
100,000 W -9765 W 480.0 V 850.0 V 98.05%
CSI Solar Co Ltd: CSI-100K-T480GL02-U {480V}
CSI Solar Co Ltd
100,000 W -9765 W 480.0 V 850.0 V 98.25%
Ginlong Technologies Co Ltd: Solis-100K-5G-US {480V}
Ginlong Technologies Co Ltd
100,000 W -9765 W 480.0 V 850.0 V 98.25%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}?

Check KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} (109,765 W AC, 175 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V}.

KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} Panel & Wire Spec

Size 75 C copper conductors at 2/0 AWG Cu on a 175 A OCPD breaker (132.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.44%) and MPPT window (705-1,300 V) directly against Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V} (100,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} by KACO new energy GmbH covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} require?

At 109,765 W continuous AC (480 V, 3-phase), continuous current is 132.0 A; 125% NEC 690.8/705.12 sizing requires a 175 A breaker and 2/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} require?

At 109,765 W AC and 480 V, 3-phase, continuous line current is 132.0 A, requiring a 175 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} compare to Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V}?

KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V} delivers 109,765 W AC at 98.44% CEC efficiency with a 1,300 V DC ceiling, while Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V} outputs 100,000 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.