Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} — CEC Inverter Specifications

Manufacturer: JingTsing Technology Ltd Registry: CEC Verified Engineering Specification

JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} outputs 459,563 W AC at 740 V, 3-phase (358.6 A continuous, 450 A OCPD), ranking #81 of 2,343 CEC inverters at 98.48% efficiency with a 1,100-1,600 V MPPT window and 1,600 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
459,563 W
AC Voltage
740 V, 3-phase
Min PV Breaker
450 A (parallel Cu feeders)
CEC Efficiency
98.48%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} Compare Against Peer CEC Listings?

CEC efficiency rank (#81), 1,100-1,600 V MPPT tracking, and panel fit for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}.

Operating at 740 V, 3-phase, JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} converts DC array energy at 98.48% CEC weighted efficiency (top 3.6%; higher than 96.4% of peers) with a 1,600 V max DC input and 333.323 A max input current for NEC 690.7 string safety. Compare this 459,563 W grid-tied PV inverter directly with EPC Power Corp: 50-200100 {720V} (561,806 W). Commercial 740 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (740V) or NEC 705.11 supply-side tap.

Where Does JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} at 459,563 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (459,563 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACJingTsing Technolo: 459,563 W

What Dataset Percentiles Define JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

Dataset percentiles comparing JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} against 2,343 certified grid-support inverters nationwide. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} Technical ThresholdsPercentile comparison for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output459,563 WCEC Efficiency98.48%Backfeed Breaker450 A

What Do the Dataset Ranks Show for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

Engineering highlights for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #81 / 2,343

98.48% CEC Weighted Efficiency

equal to the 98.48% 740 V median; overall power rank #205 (459,563 W, top 8.7%; higher than 91.3% of peers).

NEC 705.12 Check

450 A Required Backfeed OCPD

125% x 358.6 A = 448.2 A -> 450 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

1,100 V - 1,600 V (Max 1,600 V DC)

Tracking span of 500.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 740 V, 3-phase switchgear (200A Bus / 200A Main (740V) to 1,200A Bus / 1,200A Main (740V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 459563.0W / 740 V 3-phase -> 358.6 A | Breaker >= 1.25 * 358.6 = 448.2 A -> 450 A

CEC Inverters.csv for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}: Paco=459563.0 W, Vac=740 V, Vdcmax=1600.0 V, Eff=98.48%.

Result: Min 450 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (740V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

California Energy Commission Solar Equipment List parameters for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 459,563 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 740 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,600 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 1,100 V - 1,600 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 333.323 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.48% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (740 V, 3-phase)?

Panelboard and switchgear backfeed allowances for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (450 A OCPD). Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (450 A required OCPD at 740 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (740V) 40 A 450 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (740V) 80 A 450 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (740V) 120 A 450 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (740V) 160 A 450 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (740V) 240 A 450 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sampled CEC PV modules aligned within 1100.0-1600.0 V MPPT and 1600.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 26 to 28 panels 16.52 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 33 to 37 panels 16.28 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 32 to 35 panels 14.88 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 39 panels (fixed) 7.8 kW

Which Competing Grid-Support Inverters Compare to JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

Four alternative CEC inverters matched to JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (459,563 W AC), led by EPC Power Corp: 50-200100 {720V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EPC Power Corp: 50-200100 {720V}
EPC Power Corp
561,806 W +102243 W 720.0 V 1500.0 V 98.58%
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -279989 W 800.0 V 1200.0 V 97.39%
LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V}
LS Energy Solutions LLC
139,449 W -320114 W 600.0 V 1350.0 V 98.27%
SMA America: SHP FLEX-US-21 {385V}
SMA America
100,842 W -358721 W 385.0 V 1195.0 V 97.8%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}?

Check JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} (459,563 W AC, 450 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 740 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (740V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,600 V DC on JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V}.

JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 450 A OCPD breaker (358.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.48%) and MPPT window (1,100-1,600 V) directly against EPC Power Corp: 50-200100 {720V} (561,806 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} by JingTsing Technology Ltd covering breaker sizing, MPPT limits, and 740 V, 3-phase interconnection.

What breaker and wire size does JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} require?

At 459,563 W continuous AC (740 V, 3-phase), continuous current is 358.6 A; 125% NEC 690.8/705.12 sizing requires a 450 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} require?

At 459,563 W AC and 740 V, 3-phase, continuous line current is 358.6 A, requiring a 450 A OCPD and 1,200A Bus / 1,200A Main (740V) or NEC 705.11 interconnection.

How does JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} compare to EPC Power Corp: 50-200100 {720V}?

JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V} delivers 459,563 W AC at 98.48% CEC efficiency with a 1,600 V DC ceiling, while EPC Power Corp: 50-200100 {720V} outputs 561,806 W at 740 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.