Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} outputs 11,257 W AC at 240 V (46.9 A continuous, 60 A OCPD), ranking #1,315 of 2,343 CEC inverters at 96.64% efficiency with a 210-550 V MPPT window and 550 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 11,257 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 96.64%
How Does Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}.
Rated at 11,257 W AC (46.9 A continuous), Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} ranks #1,315 of 2,343 CEC units at 96.64% efficiency (-0.04 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 60 A circuit is 6 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 550 V DC at record local winter lows.
Where Does Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} Fall Across Listed CEC Models?
Marks Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} (11,257 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Benchmarks Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} continuous AC output, 96.64% CEC weighted efficiency, and 60 A OCPD breaker demand.
What Do the Dataset Ranks Show for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} by Jiangsu Weiheng Intelligent Technology Co Ltd.
96.64% CEC Weighted Efficiency
-0.04 pts vs the 96.68% 240 V median; overall power rank #808 (11,257 W, top 34.5%; higher than 65.5% of peers).
60 A Required Backfeed OCPD
125% x 46.9 A = 58.6 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
210 V - 550 V (Max 550 V DC)
Tracking span of 340.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 11257.0W / 240 V -> 46.9 A | Breaker >= 1.25 * 46.9 = 58.6 A -> 60 A
CEC Inverters.csv for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}: Paco=11257.0 W, Vac=240 V, Vdcmax=550.0 V, Eff=96.64%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 11,257 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 550 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 210 V - 550 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 28.4102 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.64% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Evaluates Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Sample PV string lengths aligned within 210-550 V MPPT and 550 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 5 to 9 panels | 5.31 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 7 to 13 panels | 5.72 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 7 to 12 panels | 5.1 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 8 to 13 panels | 2.6 kW |
Which Competing Grid-Support Inverters Compare to Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Competing CEC grid-support inverters near 11,257 W AC and 240 V, led by Chint Power Systems America: CPS ECH114KTL/US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH114KTL/US {240V} Chint Power Systems America |
11,360 W | +103 W | 240.0 V | 480.0 V | 96.53% |
| Altenergy Power System Inc: ELS-114 {240V} Altenergy Power System Inc |
11,415 W | +158 W | 240.0 V | 60.0 V | 93.08% |
| Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} Dyness Digital Energy Technology Co LTD |
11,498 W | +241 W | 240.0 V | 500.0 V | 96.41% |
| Dyness Digital Energy Technology Co LTD: TX114K-AM {240V} Dyness Digital Energy Technology Co LTD |
11,519 W | +262 W | 240.0 V | 490.0 V | 96.21% |
What Are the Interconnection Limits and Best-Fit Uses for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}?
Check Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} (11,257 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 550 V DC on Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V}.
Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (46.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.64%) and MPPT window (210-550 V) directly against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} by Jiangsu Weiheng Intelligent Technology Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} require?
At 11,257 W continuous AC (240 V), continuous current is 46.9 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?
Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V} delivers 11,257 W AC at 96.64% CEC efficiency with a 550 V DC ceiling, while Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)