Jackery Inc: GVI-HR-11K4-USG {240V} — CEC Inverter Specifications

Manufacturer: Jackery Inc Registry: CEC Verified Engineering Specification

Jackery Inc: GVI-HR-11K4-USG {240V} outputs 11,084 W AC at 240 V (46.2 A continuous, 60 A OCPD), ranking #583 of 2,343 CEC inverters at 97.42% efficiency with a 245-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,084 W
AC Voltage
240 V
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Jackery Inc: GVI-HR-11K4-USG {240V} Compare Against Peer CEC Listings?

How Jackery Inc Jackery Inc: GVI-HR-11K4-USG {240V} compares on 97.42% efficiency, MPPT span, and 120% busbar interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

With a 245-450 V MPPT tracking band and 450 V DC ceiling, Jackery Inc: GVI-HR-11K4-USG {240V} handles 11,084 W continuous AC (5,308 W above the 5,776 W 240 V median). Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap. Installers comparing Jackery Inc against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does Jackery Inc: GVI-HR-11K4-USG {240V} Fall Across Listed CEC Models?

Position of Jackery Inc: GVI-HR-11K4-USG {240V} (11,084 W AC) relative to the 7,680 W CEC median inverter. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Jackery Inc: GVI-HR-11K4-USG {240V} (11,084 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACJackery Inc: GVI-H: 11,084 W

What Dataset Percentiles Define Jackery Inc: GVI-HR-11K4-USG {240V}?

Percentile placement of Jackery Inc: GVI-HR-11K4-USG {240V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Jackery Inc: GVI-HR-11K4-USG {240V} Technical ThresholdsPercentile comparison for Jackery Inc: GVI-HR-11K4-USG {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,084 WCEC Efficiency97.42%Backfeed Breaker60 A

What Do the Dataset Ranks Show for Jackery Inc: GVI-HR-11K4-USG {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Jackery Inc: GVI-HR-11K4-USG {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Eff #583 / 2,343

97.42% CEC Weighted Efficiency

+0.74 pts vs the 96.68% 240 V median; overall power rank #814 (11,084 W, top 34.7%; higher than 65.3% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 46.2 A = 57.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

245 V - 450 V (Max 450 V DC)

Tracking span of 205.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

Needs Derate / Tap 705.11

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11084.0W / 240 V -> 46.2 A | Breaker >= 1.25 * 46.2 = 57.8 A -> 60 A

CEC Inverters.csv for Jackery Inc: GVI-HR-11K4-USG {240V}: Paco=11084.0 W, Vac=240 V, Vdcmax=450.0 V, Eff=97.42%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.

What Are the Published CEC Specifications for Jackery Inc: GVI-HR-11K4-USG {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Jackery Inc: GVI-HR-11K4-USG {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Jackery Inc: GVI-HR-11K4-USG {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,084 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 450 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 245 V - 450 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.9398 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.42% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Jackery Inc: GVI-HR-11K4-USG {240V}?

Check whether Jackery Inc: GVI-HR-11K4-USG {240V} (60 A breaker) fits without main breaker derate or supply-side taps. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Jackery Inc: GVI-HR-11K4-USG {240V} (60 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 60 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 60 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 60 A Needs Derate / Tap 705.11
200A Bus / 175A Main 65 A 60 A PASS (120% Rule)
225A Bus / 200A Main 70 A 60 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Jackery Inc: GVI-HR-11K4-USG {240V}?

Verified cold-weather (-10 C) series module counts matched to Jackery Inc: GVI-HR-11K4-USG {240V}'s 450 V DC ceiling.

Sampled CEC PV modules aligned within 245.0-450.0 V MPPT and 450.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 10 panels 4.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Jackery Inc: GVI-HR-11K4-USG {240V}?

Alternative CEC inverters comparable to Jackery Inc: GVI-HR-11K4-USG {240V}, including Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECH114KTL/US {240V}
Chint Power Systems America
11,360 W +276 W 240.0 V 480.0 V 96.53%
Altenergy Power System Inc: ELS-114 {240V}
Altenergy Power System Inc
11,415 W +331 W 240.0 V 60.0 V 93.08%
Dyness Digital Energy Technology Co LTD: TX114K-HM {240V}
Dyness Digital Energy Technology Co LTD
11,498 W +414 W 240.0 V 500.0 V 96.41%
Dyness Digital Energy Technology Co LTD: TX114K-AM {240V}
Dyness Digital Energy Technology Co LTD
11,519 W +435 W 240.0 V 490.0 V 96.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Jackery Inc: GVI-HR-11K4-USG {240V}?

Check Jackery Inc: GVI-HR-11K4-USG {240V} (11,084 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on Jackery Inc: GVI-HR-11K4-USG {240V}.

Jackery Inc: GVI-HR-11K4-USG {240V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (46.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.42%) and MPPT window (245-450 V) directly against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Jackery Inc: GVI-HR-11K4-USG {240V} by Jackery Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Jackery Inc: GVI-HR-11K4-USG {240V} require?

At 11,084 W continuous AC (240 V), continuous current is 46.2 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

Does Jackery Inc: GVI-HR-11K4-USG {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.

How does Jackery Inc: GVI-HR-11K4-USG {240V} compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?

Jackery Inc: GVI-HR-11K4-USG {240V} delivers 11,084 W AC at 97.42% CEC efficiency with a 450 V DC ceiling, while Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?