Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Ginlong Technologies Co Ltd: S6-GC50K-US {480V} — CEC Inverter Specifications

Manufacturer: Ginlong Technologies Co Ltd Registry: CEC Verified Engineering Specification

Ginlong Technologies Co Ltd: S6-GC50K-US {480V} outputs 49,848 W AC at 480 V, 3-phase (60.0 A continuous, 80 A OCPD), ranking #193 of 2,343 CEC inverters at 98.29% efficiency with a 580-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
49,848 W
AC Voltage
480 V, 3-phase
Min PV Breaker
80 A (4 AWG Cu)
CEC Efficiency
98.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Ginlong Technologies Co Ltd: S6-GC50K-US {480V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}.

Ranking #457 of 2,343 CEC inverters (top 19.6%; higher than 80.4% of peers), Ginlong Technologies Co Ltd: S6-GC50K-US {480V} is a grid-tied PV inverter delivering 49,848 W continuous AC at 480 V, 3-phase (60.0 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.29% (+0.27 pts vs the 98.02% 480 V median) against peers like CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V} (49,848 W).

Where Does Ginlong Technologies Co Ltd: S6-GC50K-US {480V} Fall Across Listed CEC Models?

Marks Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (49,848 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (49,848 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGinlong Technologi: 49,848 W

What Dataset Percentiles Define Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Benchmarks Ginlong Technologies Co Ltd: S6-GC50K-US {480V} continuous AC output, 98.29% CEC weighted efficiency, and 80 A OCPD breaker demand.

Ginlong Technologies Co Ltd: S6-GC50K-US {480V} Technical ThresholdsPercentile comparison for Ginlong Technologies Co Ltd: S6-GC50K-US {480V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output49,848 WCEC Efficiency98.29%Backfeed Breaker80 A

What Do the Dataset Ranks Show for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Four key NEC 705.12 and California Energy Commission metrics defining Ginlong Technologies Co Ltd: S6-GC50K-US {480V} by Ginlong Technologies Co Ltd.

Eff #193 / 2,343

98.29% CEC Weighted Efficiency

+0.27 pts vs the 98.02% 480 V median; overall power rank #457 (49,848 W, top 19.6%; higher than 80.4% of peers).

NEC 705.12 Check

80 A Required Backfeed OCPD

125% x 60.0 A = 75.0 A -> 80 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

580 V - 850 V (Max 850 V DC)

Tracking span of 270.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 49848.0W / 480 V 3-phase -> 60.0 A | Breaker >= 1.25 * 60.0 = 75.0 A -> 80 A

CEC Inverters.csv for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}: Paco=49848.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.29%.

Result: Min 80 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}.

Official California Energy Commission (NREL SAM) test parameters for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 49,848 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 480 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 850 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 580 V - 850 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 70.4372 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.29% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (480 V, 3-phase)?

Evaluates Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (80 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (80 A required OCPD at 480 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (480V) 40 A 80 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (480V) 80 A 80 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (480V) 120 A 80 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (480V) 160 A 80 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (480V) 240 A 80 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Sample PV string lengths aligned within 580-850 V MPPT and 850 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sampled CEC PV modules aligned within 580.0-850.0 V MPPT and 850.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 14 to 15 panels 8.85 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 18 to 20 panels 8.8 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 17 to 18 panels 7.65 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 15 panels (fixed) 7.72 kW

Which Competing Grid-Support Inverters Compare to Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Competing CEC grid-support inverters near 49,848 W AC and 480 V, 3-phase, led by CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V}
CSI Solar Co Ltd
49,848 W Tie (0 W) 480.0 V 850.0 V 98.29%
Fortress Power LLC: FP-Nano-50k-N {480V}
Fortress Power LLC
49,803 W -45 W 480.0 V 850.0 V 97.41%
CSI Solar Co Ltd: CSI-50K-T480GL01-UB {480V}
CSI Solar Co Ltd
49,916 W +68 W 480.0 V 850.0 V 98.32%
ABB: TRIO-500-TL-OUTD-US-480 {480V}
ABB
50,000 W +152 W 480.0 V 800.0 V 98.27%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Ginlong Technologies Co Ltd: S6-GC50K-US {480V}?

Check Ginlong Technologies Co Ltd: S6-GC50K-US {480V} (49,848 W AC, 80 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on Ginlong Technologies Co Ltd: S6-GC50K-US {480V}.

Ginlong Technologies Co Ltd: S6-GC50K-US {480V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on an 80 A OCPD breaker (60.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.29%) and MPPT window (580-850 V) directly against CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V} (49,848 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Ginlong Technologies Co Ltd: S6-GC50K-US {480V} by Ginlong Technologies Co Ltd covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.

What breaker and wire size does Ginlong Technologies Co Ltd: S6-GC50K-US {480V} require?

At 49,848 W continuous AC (480 V, 3-phase), continuous current is 60.0 A; 125% NEC 690.8/705.12 sizing requires an 80 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Ginlong Technologies Co Ltd: S6-GC50K-US {480V} require?

At 49,848 W AC and 480 V, 3-phase, continuous line current is 60.0 A, requiring an 80 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.

How does Ginlong Technologies Co Ltd: S6-GC50K-US {480V} compare to CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V}?

Ginlong Technologies Co Ltd: S6-GC50K-US {480V} delivers 49,848 W AC at 98.29% CEC efficiency with a 850 V DC ceiling, while CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V} outputs 49,848 W at 480 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.