Manufacturer: FranklinWH Energy Storage Inc Registry: CEC Verified Engineering Specification

FranklinWH Energy Storage Inc: aPower Syyy {208V} outputs 9,785 W AC at 208 V, commercial single-phase (47.0 A continuous, 60 A OCPD), ranking #564 of 2,343 CEC inverters at 97.45% efficiency with a 250-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
9,785 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
60 A (6 AWG Cu)
CEC Efficiency
97.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FranklinWH Energy Storage Inc: aPower Syyy {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#564), 250-480 V MPPT tracking, and panel fit for FranklinWH Energy Storage Inc: aPower Syyy {208V}.

FranklinWH Energy Storage Inc: aPower Syyy {208V} from FranklinWH Energy Storage Inc outputs 47.0 A continuous AC at 208 V, commercial single-phase (9,785 W AC, rank #943). Paired with 6 AWG Cu conductors and a 60 A OCPD, its 97.45% CEC efficiency compares closely with Altenergy Power System Inc: ELS-114 {208V} (10,011 W). Keep NEC 690.7 winter string Voc below 480 V DC.

Where Does FranklinWH Energy Storage Inc: aPower Syyy {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting FranklinWH Energy Storage Inc: aPower Syyy {208V} at 9,785 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where FranklinWH Energy Storage Inc: aPower Syyy {208V} (9,785 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFranklinWH Energy : 9,785 W

What Dataset Percentiles Define FranklinWH Energy Storage Inc: aPower Syyy {208V}?

Dataset percentiles comparing FranklinWH Energy Storage Inc: aPower Syyy {208V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

FranklinWH Energy Storage Inc: aPower Syyy {208V} Technical ThresholdsPercentile comparison for FranklinWH Energy Storage Inc: aPower Syyy {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output9,785 WCEC Efficiency97.45%Backfeed Breaker60 A

What Do the Dataset Ranks Show for FranklinWH Energy Storage Inc: aPower Syyy {208V}?

Engineering highlights for FranklinWH Energy Storage Inc: aPower Syyy {208V} covering efficiency, 6 AWG Cu feeder, and panel compatibility.

Eff #564 / 2,343

97.45% CEC Weighted Efficiency

+1.04 pts vs the 96.41% 208 V median; overall power rank #943 (9,785 W, top 40.2%; higher than 59.8% of peers).

NEC 705.12 Check

60 A Required Backfeed OCPD

125% x 47.0 A = 58.8 A -> 60 A standard OCPD using 6 AWG Cu (75 C).

MPPT Window

250 V - 480 V (Max 480 V DC)

Tracking span of 230.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 9785.1W / 208 V -> 47.0 A | Breaker >= 1.25 * 47.0 = 58.8 A -> 60 A

CEC Inverters.csv for FranklinWH Energy Storage Inc: aPower Syyy {208V}: Paco=9785.1 W, Vac=208 V, Vdcmax=480.0 V, Eff=97.45%.

Result: Min 60 A breaker & 6 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for FranklinWH Energy Storage Inc: aPower Syyy {208V}?

California Energy Commission Solar Equipment List parameters for FranklinWH Energy Storage Inc: aPower Syyy {208V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for FranklinWH Energy Storage Inc: aPower Syyy {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 9,785 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 250 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 25.1023 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.45% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to FranklinWH Energy Storage Inc: aPower Syyy {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for FranklinWH Energy Storage Inc: aPower Syyy {208V} (60 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates FranklinWH Energy Storage Inc: aPower Syyy {208V} (60 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 60 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 60 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 60 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 60 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 60 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With FranklinWH Energy Storage Inc: aPower Syyy {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for FranklinWH Energy Storage Inc: aPower Syyy {208V}.

Sampled CEC PV modules aligned within 250.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to FranklinWH Energy Storage Inc: aPower Syyy {208V}?

Four alternative CEC inverters matched to FranklinWH Energy Storage Inc: aPower Syyy {208V} (9,785 W AC), led by Altenergy Power System Inc: ELS-114 {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: ELS-114 {208V}
Altenergy Power System Inc
10,011 W +226 W 208.0 V 60.0 V 92.83%
Chint Power Systems America: CPS ECH96KTL/US {208V}
Chint Power Systems America
9,550 W -235 W 208.0 V 480.0 V 96.73%
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W +272 W 208.0 V 480.0 V 96.7%
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W +714 W 208.0 V 480.0 V 96.07%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for FranklinWH Energy Storage Inc: aPower Syyy {208V}?

Check FranklinWH Energy Storage Inc: aPower Syyy {208V} (9,785 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on FranklinWH Energy Storage Inc: aPower Syyy {208V}.

FranklinWH Energy Storage Inc: aPower Syyy {208V} Panel & Wire Spec

Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.45%) and MPPT window (250-480 V) directly against Altenergy Power System Inc: ELS-114 {208V} (10,011 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for FranklinWH Energy Storage Inc: aPower Syyy {208V} by FranklinWH Energy Storage Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does FranklinWH Energy Storage Inc: aPower Syyy {208V} require?

At 9,785 W continuous AC (208 V, commercial single-phase), continuous current is 47.0 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does FranklinWH Energy Storage Inc: aPower Syyy {208V} require?

At 9,785 W AC and 208 V, commercial single-phase, continuous line current is 47.0 A, requiring a 60 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does FranklinWH Energy Storage Inc: aPower Syyy {208V} compare to Altenergy Power System Inc: ELS-114 {208V}?

FranklinWH Energy Storage Inc: aPower Syyy {208V} delivers 9,785 W AC at 97.45% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-114 {208V} outputs 10,011 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.