FOXESS CO LTD: H1-57-US {240V} — CEC Inverter Specifications

Manufacturer: FOXESS CO LTD Registry: CEC Verified Engineering Specification

FOXESS CO LTD: H1-57-US {240V} outputs 5,748 W AC at 240 V (24.0 A continuous, 30 A OCPD), ranking #583 of 2,343 CEC inverters at 97.42% efficiency with a 204-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,748 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
97.42%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FOXESS CO LTD: H1-57-US {240V} Compare Against Peer CEC Listings?

How FOXESS CO LTD FOXESS CO LTD: H1-57-US {240V} compares on 97.42% efficiency, MPPT span, and 120% busbar interconnection.

With a 204-480 V MPPT tracking band and 480 V DC ceiling, FOXESS CO LTD: H1-57-US {240V} handles 5,748 W continuous AC (28 W below the 5,776 W 240 V median). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing FOXESS CO LTD against Delta Electronics: E6-TL-US {240V} (5,760 W) should verify whether listed since 2024-02-12 grid-support firmware meets local IEEE 1547 utility rules.

Where Does FOXESS CO LTD: H1-57-US {240V} Fall Across Listed CEC Models?

Position of FOXESS CO LTD: H1-57-US {240V} (5,748 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where FOXESS CO LTD: H1-57-US {240V} (5,748 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACFOXESS CO LTD: H1-: 5,748 W

What Dataset Percentiles Define FOXESS CO LTD: H1-57-US {240V}?

Percentile placement of FOXESS CO LTD: H1-57-US {240V} across AC power class, conversion efficiency, and backfeed breaker size.

FOXESS CO LTD: H1-57-US {240V} Technical ThresholdsPercentile comparison for FOXESS CO LTD: H1-57-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,748 WCEC Efficiency97.42%Backfeed Breaker30 A

What Do the Dataset Ranks Show for FOXESS CO LTD: H1-57-US {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for FOXESS CO LTD: H1-57-US {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #583 / 2,343

97.42% CEC Weighted Efficiency

+0.74 pts vs the 96.68% 240 V median; overall power rank #1,439 (5,748 W, below CEC median; higher than 38.5% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 24.0 A = 30.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

204 V - 480 V (Max 480 V DC)

Tracking span of 276.0 V; listed since 2024-02-12 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5748.2W / 240 V -> 24.0 A | Breaker >= 1.25 * 24.0 = 30.0 A -> 30 A

CEC Inverters.csv for FOXESS CO LTD: H1-57-US {240V}: Paco=5748.2 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.42%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for FOXESS CO LTD: H1-57-US {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for FOXESS CO LTD: H1-57-US {240V}.

Official California Energy Commission (NREL SAM) test parameters for FOXESS CO LTD: H1-57-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,748 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 204 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 15.5269 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.42% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-02-12 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for FOXESS CO LTD: H1-57-US {240V}?

Check whether FOXESS CO LTD: H1-57-US {240V} (30 A breaker) fits without main breaker derate or supply-side taps.

Evaluates FOXESS CO LTD: H1-57-US {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which CEC PV Module Strings Pair With FOXESS CO LTD: H1-57-US {240V}?

Verified cold-weather (-10 C) series module counts matched to FOXESS CO LTD: H1-57-US {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 204.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 7 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 8 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to FOXESS CO LTD: H1-57-US {240V}?

Alternative CEC inverters comparable to FOXESS CO LTD: H1-57-US {240V}, including Delta Electronics: E6-TL-US {240V} (5,760 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: E6-TL-US {240V}
Delta Electronics
5,760 W +12 W 240.0 V 480.0 V 97.35%
Delta Electronics: M6-TL-US {240V}
Delta Electronics
5,760 W +12 W 240.0 V 480.0 V 97.37%
Delta Electronics: E6_BDI {240V}
Delta Electronics
5,823 W +75 W 240.0 V 480.0 V 97.63%
Base Power Inc: MIN 6000TL-XH-US {240V}
Base Power Inc
5,918 W +170 W 240.0 V 480.0 V 97.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for FOXESS CO LTD: H1-57-US {240V}?

Check FOXESS CO LTD: H1-57-US {240V} (5,748 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on FOXESS CO LTD: H1-57-US {240V}.

FOXESS CO LTD: H1-57-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (24.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.42%) and MPPT window (204-480 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for FOXESS CO LTD: H1-57-US {240V} by FOXESS CO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does FOXESS CO LTD: H1-57-US {240V} require?

At 5,748 W continuous AC (240 V), continuous current is 24.0 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does FOXESS CO LTD: H1-57-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does FOXESS CO LTD: H1-57-US {240V} compare to Delta Electronics: E6-TL-US {240V}?

FOXESS CO LTD: H1-57-US {240V} delivers 5,748 W AC at 97.42% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.