FOXESS CO LTD: AC1-57-US {240V} outputs 5,724 W AC at 240 V (23.8 A continuous, 30 A OCPD), ranking #868 of 2,343 CEC inverters at 97.12% efficiency with a 140-460 V MPPT window and 460 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,724 W
- AC Voltage
- 240 V
- Min PV Breaker
- 30 A (10 AWG Cu)
- CEC Efficiency
- 97.12%
How Does FOXESS CO LTD: AC1-57-US {240V} Compare Against Peer CEC Listings?
How FOXESS CO LTD FOXESS CO LTD: AC1-57-US {240V} compares on 97.12% efficiency, MPPT span, and 120% busbar interconnection.
FOXESS CO LTD certifies FOXESS CO LTD: AC1-57-US {240V} (grid-tied PV inverter, listed since 2024-02-12) at 5,724 W AC (52 W below the 5,776 W 240 V median). Its 460 V DC ceiling pairs with an MPPT window of 140-460 V (span 320.0 V). Under NEC 690.8/705.12, 125% sizing demands 10 AWG Cu conductors on a 30 A OCPD.
Where Does FOXESS CO LTD: AC1-57-US {240V} Fall Across Listed CEC Models?
Position of FOXESS CO LTD: AC1-57-US {240V} (5,724 W AC) relative to the 7,680 W CEC median inverter.
What Dataset Percentiles Define FOXESS CO LTD: AC1-57-US {240V}?
Percentile placement of FOXESS CO LTD: AC1-57-US {240V} across AC power class, conversion efficiency, and backfeed breaker size.
What Do the Dataset Ranks Show for FOXESS CO LTD: AC1-57-US {240V}?
Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for FOXESS CO LTD: AC1-57-US {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
97.12% CEC Weighted Efficiency
+0.44 pts vs the 96.68% 240 V median; overall power rank #1,447 (5,724 W, below CEC median; higher than 38.2% of peers).
30 A Required Backfeed OCPD
125% x 23.8 A = 29.8 A -> 30 A standard OCPD using 10 AWG Cu (75 C).
140 V - 460 V (Max 460 V DC)
Tracking span of 320.0 V; listed since 2024-02-12 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5723.5W / 240 V -> 23.8 A | Breaker >= 1.25 * 23.8 = 29.8 A -> 30 A
CEC Inverters.csv for FOXESS CO LTD: AC1-57-US {240V}: Paco=5723.5 W, Vac=240 V, Vdcmax=460.0 V, Eff=97.12%.
Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for FOXESS CO LTD: AC1-57-US {240V}?
Official California Energy Commission electrical test parameters, AC voltage, and DC limits for FOXESS CO LTD: AC1-57-US {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,724 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 460 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 140 V - 460 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 16.3701 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.12% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-02-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for FOXESS CO LTD: AC1-57-US {240V}?
Check whether FOXESS CO LTD: AC1-57-US {240V} (30 A breaker) fits without main breaker derate or supply-side taps.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 30 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 30 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 30 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 30 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 30 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With FOXESS CO LTD: AC1-57-US {240V}?
Verified cold-weather (-10 C) series module counts matched to FOXESS CO LTD: AC1-57-US {240V}'s 460 V DC ceiling.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 5 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 5 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to FOXESS CO LTD: AC1-57-US {240V}?
Alternative CEC inverters comparable to FOXESS CO LTD: AC1-57-US {240V}, including Delta Electronics: E6-TL-US {240V} (5,760 W) at 240 V.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E6-TL-US {240V} Delta Electronics |
5,760 W | +36 W | 240.0 V | 480.0 V | 97.35% |
| Delta Electronics: M6-TL-US {240V} Delta Electronics |
5,760 W | +36 W | 240.0 V | 480.0 V | 97.37% |
| Delta Electronics: E6_BDI {240V} Delta Electronics |
5,823 W | +100 W | 240.0 V | 480.0 V | 97.63% |
| Base Power Inc: MIN 6000TL-XH-US {240V} Base Power Inc |
5,918 W | +194 W | 240.0 V | 480.0 V | 97.26% |
What Are the Interconnection Limits and Best-Fit Uses for FOXESS CO LTD: AC1-57-US {240V}?
Check FOXESS CO LTD: AC1-57-US {240V} (5,724 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 460 V DC on FOXESS CO LTD: AC1-57-US {240V}.
FOXESS CO LTD: AC1-57-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (23.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.12%) and MPPT window (140-460 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for FOXESS CO LTD: AC1-57-US {240V} by FOXESS CO LTD covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does FOXESS CO LTD: AC1-57-US {240V} require?
At 5,724 W continuous AC (240 V), continuous current is 23.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.
Does FOXESS CO LTD: AC1-57-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).
How does FOXESS CO LTD: AC1-57-US {240V} compare to Delta Electronics: E6-TL-US {240V}?
FOXESS CO LTD: AC1-57-US {240V} delivers 5,724 W AC at 97.12% CEC efficiency with a 460 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)