Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} outputs 11,349 W AC at 240 V (47.3 A continuous, 60 A OCPD), ranking #2,190 of 2,343 CEC inverters at 95.41% efficiency with a 250-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 11,349 W
- AC Voltage
- 240 V
- Min PV Breaker
- 60 A (6 AWG Cu)
- CEC Efficiency
- 95.41%
How Does Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}.
Rated at 11,349 W AC (47.3 A continuous), Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} ranks #2,190 of 2,343 CEC units at 95.41% efficiency (-1.27 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 60 A circuit is 6 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.
Where Does Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} Fall Across Listed CEC Models?
Marks Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} (11,349 W AC) across the California Energy Commission inverter AC capacity distribution.
What Dataset Percentiles Define Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Benchmarks Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} continuous AC output, 95.41% CEC weighted efficiency, and 60 A OCPD breaker demand.
What Do the Dataset Ranks Show for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} by Eternalplanet Energy Co Ltd.
95.41% CEC Weighted Efficiency
-1.27 pts vs the 96.68% 240 V median; overall power rank #800 (11,349 W, top 34.2%; higher than 65.8% of peers).
60 A Required Backfeed OCPD
125% x 47.3 A = 59.1 A -> 60 A standard OCPD using 6 AWG Cu (75 C).
250 V - 480 V (Max 480 V DC)
Tracking span of 230.0 V; listed since 2026-01-12 (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 11349.0W / 240 V -> 47.3 A | Breaker >= 1.25 * 47.3 = 59.1 A -> 60 A
CEC Inverters.csv for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}: Paco=11349.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=95.41%.
Result: Min 60 A breaker & 6 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 11,349 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 250 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 31.7184 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2026-01-12 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Evaluates Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} (60 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 60 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 60 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 60 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 60 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Sample PV string lengths aligned within 250-480 V MPPT and 480 V DC max at -10 C. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Competing CEC grid-support inverters near 11,349 W AC and 240 V, led by Chint Power Systems America: CPS ECH114KTL/US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH114KTL/US {240V} Chint Power Systems America |
11,360 W | +11 W | 240.0 V | 480.0 V | 96.53% |
| Altenergy Power System Inc: ELS-114 {240V} Altenergy Power System Inc |
11,415 W | +66 W | 240.0 V | 60.0 V | 93.08% |
| Dyness Digital Energy Technology Co LTD: TX114K-HM {240V} Dyness Digital Energy Technology Co LTD |
11,498 W | +149 W | 240.0 V | 500.0 V | 96.41% |
| Dyness Digital Energy Technology Co LTD: TX114K-AM {240V} Dyness Digital Energy Technology Co LTD |
11,519 W | +170 W | 240.0 V | 490.0 V | 96.21% |
What Are the Interconnection Limits and Best-Fit Uses for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}?
Check Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} (11,349 W AC, 60 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 60 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V}.
Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} Panel & Wire Spec
Size 75 C copper conductors at 6 AWG Cu on a 60 A OCPD breaker (47.3 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.41%) and MPPT window (250-480 V) directly against Chint Power Systems America: CPS ECH114KTL/US {240V} (11,360 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} by Eternalplanet Energy Co Ltd covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} require?
At 11,349 W continuous AC (240 V), continuous current is 47.3 A; 125% NEC 690.8/705.12 sizing requires a 60 A breaker and 6 AWG Cu (75 C) wire.
Does Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 60 A at 240 V means Needs Derate / Tap 705.11.
How does Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} compare to Chint Power Systems America: CPS ECH114KTL/US {240V}?
Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V} delivers 11,349 W AC at 95.41% CEC efficiency with a 480 V DC ceiling, while Chint Power Systems America: CPS ECH114KTL/US {240V} outputs 11,360 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)