Enphase Energy Inc: IQ7A-72-5-US {240V} outputs 349 W AC at 240 V (1.5 A continuous, 15 A OCPD), ranking #1,548 of 2,343 CEC inverters at 96.5% efficiency with a 38-43 V MPPT window and 43 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 349 W
- AC Voltage
- 240 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.5%
How Does Enphase Energy Inc: IQ7A-72-5-US {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,548), 38-43 V MPPT tracking, and panel fit for Enphase Energy Inc: IQ7A-72-5-US {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Enphase Energy Inc: IQ7A-72-5-US {240V} from Enphase Energy Inc outputs 1.5 A continuous AC at 240 V (349 W AC, rank #2,051). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.5% CEC efficiency compares closely with Aptos Solar Technology LLC: MAC-400 {240V} (382 W). Keep NEC 690.7 winter string Voc below 43 V DC.
Where Does Enphase Energy Inc: IQ7A-72-5-US {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Enphase Energy Inc: IQ7A-72-5-US {240V} at 349 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Enphase Energy Inc: IQ7A-72-5-US {240V}?
Dataset percentiles comparing Enphase Energy Inc: IQ7A-72-5-US {240V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for Enphase Energy Inc: IQ7A-72-5-US {240V}?
Engineering highlights for Enphase Energy Inc: IQ7A-72-5-US {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
96.5% CEC Weighted Efficiency
-0.18 pts vs the 96.68% 240 V median; overall power rank #2,051 (349 W, below CEC median; higher than 9.9% of peers).
15 A Required Backfeed OCPD
125% x 1.5 A = 1.9 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
38 V - 43 V (Max 43 V DC)
Tracking span of 5.0 V; listed since 2022-11-01 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 349.0W / 240 V -> 1.5 A | Breaker >= 1.25 * 1.5 = 1.9 A -> 15 A
CEC Inverters.csv for Enphase Energy Inc: IQ7A-72-5-US {240V}: Paco=349.0 W, Vac=240 V, Vdcmax=43.0 V, Eff=96.5%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for Enphase Energy Inc: IQ7A-72-5-US {240V}?
California Energy Commission Solar Equipment List parameters for Enphase Energy Inc: IQ7A-72-5-US {240V} (grid-tied PV inverter) interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 349 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 43 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 38 V - 43 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 8.9294 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.5% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2022-11-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Enphase Energy Inc: IQ7A-72-5-US {240V}?
Panelboard and switchgear backfeed allowances for Enphase Energy Inc: IQ7A-72-5-US {240V} (15 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 15 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 15 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 15 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 15 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Enphase Energy Inc: IQ7A-72-5-US {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Enphase Energy Inc: IQ7A-72-5-US {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW | 270.0 W | 42.56 V | 1 panel (micro/module) | 0.27 kW |
Which Competing Grid-Support Inverters Compare to Enphase Energy Inc: IQ7A-72-5-US {240V}?
Four alternative CEC inverters matched to Enphase Energy Inc: IQ7A-72-5-US {240V} (349 W AC), led by Aptos Solar Technology LLC: MAC-400 {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC: MAC-400 {240V} Aptos Solar Technology LLC |
382 W | +34 W | 240.0 V | 48.0 V | 96.52% |
| Aptos Solar Technology LLC: MAC-400R {240V} Aptos Solar Technology LLC |
382 W | +34 W | 240.0 V | 48.0 V | 96.52% |
| Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V} Chilicon Power LLC |
289 W | -60 W | 240.0 V | 32.0 V | 95.41% |
| Altenergy Power System Inc: YC600 {240V} Altenergy Power System Inc |
550 W | +201 W | 240.0 V | 45.0 V | 96.51% |
What Are the Interconnection Limits and Best-Fit Uses for Enphase Energy Inc: IQ7A-72-5-US {240V}?
Check Enphase Energy Inc: IQ7A-72-5-US {240V} (349 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 43 V DC on Enphase Energy Inc: IQ7A-72-5-US {240V}.
Enphase Energy Inc: IQ7A-72-5-US {240V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.5 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.5%) and MPPT window (38-43 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Enphase Energy Inc: IQ7A-72-5-US {240V} by Enphase Energy Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Enphase Energy Inc: IQ7A-72-5-US {240V} require?
At 349 W continuous AC (240 V), continuous current is 1.5 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Enphase Energy Inc: IQ7A-72-5-US {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).
How does Enphase Energy Inc: IQ7A-72-5-US {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?
Enphase Energy Inc: IQ7A-72-5-US {240V} delivers 349 W AC at 96.5% CEC efficiency with a 43 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)