Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} — CEC Inverter Specifications

Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} outputs 100,000 W AC at 600 V, 3-phase (96.2 A continuous, 125 A OCPD), ranking #115 of 2,343 CEC inverters at 98.41% efficiency with a 870-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
100,000 W
AC Voltage
600 V, 3-phase
Min PV Breaker
125 A (1 AWG Cu)
CEC Efficiency
98.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} Compare Against Peer CEC Listings?

CEC efficiency rank (#115), 870-1,300 V MPPT tracking, and panel fit for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}.

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} from Chint Power Systems America outputs 96.2 A continuous AC at 600 V, 3-phase (100,000 W AC, rank #332). Paired with 1 AWG Cu conductors and a 125 A OCPD, its 98.41% CEC efficiency compares closely with Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V} (100,000 W). Keep NEC 690.7 winter string Voc below 1,300 V DC.

Where Does Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} at 100,000 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (100,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 100,000 W

What Dataset Percentiles Define Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

Dataset percentiles comparing Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} against 2,343 certified grid-support inverters nationwide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output100,000 WCEC Efficiency98.41%Backfeed Breaker125 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

Engineering highlights for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} covering efficiency, 1 AWG Cu feeder, and panel compatibility.

Eff #115 / 2,343

98.41% CEC Weighted Efficiency

+0.13 pts vs the 98.28% 600 V median; overall power rank #332 (100,000 W, top 14.5%; higher than 85.5% of peers).

NEC 705.12 Check

125 A Required Backfeed OCPD

125% x 96.2 A = 120.2 A -> 125 A standard OCPD using 1 AWG Cu (75 C).

MPPT Window

870 V - 1,300 V (Max 1,300 V DC)

Tracking span of 430.0 V; listed since 2022-06-13 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 100000.0W / 600 V 3-phase -> 96.2 A | Breaker >= 1.25 * 96.2 = 120.2 A -> 125 A

CEC Inverters.csv for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}: Paco=100000.0 W, Vac=600 V, Vdcmax=1300.0 V, Eff=98.41%.

Result: Min 125 A breaker & 1 AWG Cu (75 C); 1,200A Bus / 1,200A Main (600V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

California Energy Commission Solar Equipment List parameters for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (grid-tied PV inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 100,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 870 V - 1,300 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 101.613 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.41% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2022-06-13 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (600 V, 3-phase)?

Panelboard and switchgear backfeed allowances for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (125 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Evaluates Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (125 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 125 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 125 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (600V) 240 A 125 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}.

Sampled CEC PV modules aligned within 870.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 21 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 26 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 31 to 32 panels 6.4 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

Four alternative CEC inverters matched to Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (100,000 W AC), led by Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V}
Ginlong Technologies Co Ltd
100,000 W Tie (0 W) 600.0 V 1250.0 V 98.59%
Sungrow Power Supply Co Ltd: SC75HV {600V}
Sungrow Power Supply Co Ltd
82,500 W -17500 W 600.0 V 1300.0 V 98.0%
Delta Electronics: M125HV {600V}
Delta Electronics
124,468 W +24468 W 600.0 V 1200.0 V 98.41%
CSI Solar Co Ltd: CSI-125KTL-GS-E {600V}
CSI Solar Co Ltd
125,000 W +25000 W 600.0 V 1250.0 V 98.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}?

Check Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} (100,000 W AC, 125 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V}.

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} Panel & Wire Spec

Size 75 C copper conductors at 1 AWG Cu on a 125 A OCPD breaker (96.2 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.41%) and MPPT window (870-1,300 V) directly against Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V} (100,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} require?

At 100,000 W continuous AC (600 V, 3-phase), continuous current is 96.2 A; 125% NEC 690.8/705.12 sizing requires a 125 A breaker and 1 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} require?

At 100,000 W AC and 600 V, 3-phase, continuous line current is 96.2 A, requiring a 125 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} compare to Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V}?

Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V} delivers 100,000 W AC at 98.41% CEC efficiency with a 1,300 V DC ceiling, while Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V} outputs 100,000 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.