Skip to main content
WireAndSun
Calculators
CEC PV Module

ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M — CEC Solar Module Specifications

Manufacturer: ZNSHINE PV-TECH Co Ltd Registry: CEC Verified Engineering Specification

ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M is a 400.0 W STC (371.6 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.0% efficiency, 49.1 V Voc at 25 C, and 53.64 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
371.6 W
Voc @ 25C
49.1 V
Efficiency
20.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M (Mono-c-Si) residential solar systems.

Homeowners evaluating ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M need 15 panels for 6 kW or 20 panels (431 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.264%/C) pushes open-circuit voltage to 53.64 V at 14 F and 54.93 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M Fall Across Listed CEC Models?

Comparison of ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M (400.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZNSHINE PV-TECH Co: 400.0 W

What Dataset Percentiles Define ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

Relative ranking of ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M across nameplate watts, 92.9% PTC thermal ratio, and module aperture efficiency.

ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M Engineering BenchmarksPercentile comparison of ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention92.9%Module Efficiency20.0%

What Do the Dataset Ranks Show for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

Summary of ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M output rank, 8 kW array size (20 panels), efficiency rating, and 600 V string limit.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,442

20.0% Aperture Efficiency

Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.64 V at -10 C (590.0 V string) and 54.93 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 40.0 m2 (431 sq ft) producing 7,432 W PTC; NEC 690.8 OCPD floor is 16.08 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.1 * (1 + (-0.264/100) * (-10 - 25)) = 53.64 V | OCPD = 1.56 * 10.31 = 16.08 A

Inputs from CEC Modules.csv for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M: Voc=49.1 V, beta_Voc=-0.264%/C, Isc=10.31 A, STC=400.0 W, Area=2.0 m2.

Result: 11 panels max on 600 V (590.0 V); 20 panels for 8 kW (431 sq ft).

What Are the Published CEC Specifications for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

Complete CEC test sheet for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M including Isc (10.31 A), Voc (49.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 371.6 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.9 V / 9.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.264 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.0% (2.0 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 323 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 431 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 538 sq ft $2,503 $4,232

How Many ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M (49.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.1V and beta_Voc=-0.264%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.93 V 10 panels 549.3 V 18 panels
-10 C (14 F) 53.64 V 11 panels 590.0 V 18 panels
0 C (32 F) 52.34 V 11 panels 575.7 V 19 panels
25 C (77 F STC) 49.1 V 12 panels 589.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

Four comparable CEC modules such as CSI Solar Co Ltd CS3U-405MB-AG (405.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3U-405MB-AG
CSI Solar Co Ltd
405.0 W +5.0 W 49.3 V 20.56% 92.9%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.15% 93.4%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.05% 93.7%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.76% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

Evaluate ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M (400.0 W STC, 49.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M reaches 54.93 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 431 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (431 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M 8 kW Residential Fit

Needs 20 modules (431 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3U-405MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 371.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M by ZNSHINE PV-TECH Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M PTC wattage (371.6 W) lower than STC (400.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 371.6 W PTC (92.9% retention) across ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M's 2.0 m2 aperture.

Who should skip ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M panels (431 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3U-405MB-AG.

What is the 1,000 V commercial string limit for ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M?

On 1,000 V commercial inverters at -10 C (53.64 V cold Voc), ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.